Related Experiment Video
Updated: May 17, 2025

Retinal Pigment Epithelium Transplantation in a Non-human Primate Model for Degenerative Retinal Diseases
Published on: June 14, 2021
Human amniotic membrane graft with viscodissection and intraoperative OCT for macular hole repair
1Faculty of Medicine, University of Sherbrooke, 3001 12 Ave N, Sherbrooke, QC, J1H 5N4, Canada.
Objective:
To present the human amniotic membrane (hAM) graft with the novel addition of viscodissection and usage of intraoperative OCT as a potential approach to treating challenging macular holes and to describe the outcomes.
Design:
Retrospective interventional case series.
Participants:
10 patients with large, chronic, or persistent macular holes were included in this study.
Methods:
10 eyes of 10 patients were treated using a hAM graft with viscodissection. Intraoperative OCT was utilized to assist the placement of the graft. Outcomes were monitored through clinical examinations, retinal imaging, and OCT.
Results:
Macular holes were closed in all 10 patients and remained so during the entirety of the follow-up periods. 9 out of 10 patients experienced an improvement in visual acuity. Mean best corrected visual acuity increased from 1.68 logMAR (20/1000) preoperative to 0.74 logMAR (20/100) at 6 months postoperative. No adverse events were observed for any of our patients.
Conclusions:
The addition of viscodissection to the standard hAM graft surgery is a potential optimization that reduces risks of iatrogenic damage to the retina. Surgeons can consider including this approach as part of their arsenal to treat such macular holes.