Related Experiment Video
Updated: May 16, 2025

A Hydrogen-Deuterium Exchange Mass Spectrometry HDX-MS Platform for Investigating Peptide Biosynthetic Enzymes
Published on: May 4, 2020
Examining Instrumental Factors Influencing the Performance of Data-Independent Acquisition Methods in
Frantisek Filandr1, Morgan Hepburn1, Vladimir Sarpe1,2
1Department of Biochemistry and Molecular Biology, University of Calgary, Calgary, AB T2N 4N1, Canada.
None:
Hydrogen/deuterium exchange mass spectrometry (HX-MS) is a method used to study solution-phase protein structure and dynamics. Despite its many applications, HX-MS is limited in throughput because manual data analysis is still the norm. We previously developed HX-MS2 technology to add a second dimension of deuteration data and promote automated data processing. Data-independent acquisition (DIA) techniques enable this approach, but we require optimized methods for best performance. Using an Orbitrap Eclipse for illustration, we show that ion optics and collision energy settings typical of a proteomics DIA experiment generate maximal peptide retrieval from the DIA library. As few as three MS2 sequence ions are sufficient to generate a deuteration measurement with a precision that exceeds what is possible in traditional HX-MS. DIA window sizes are based on the chromatographic resolution of the method. An inter-scan window offset method is the recommended default configuration for most HX-DIA applications but an intra-scan overlap method can be tuned for highest performance and is recommended when maximum peptide retrieval is desired. We demonstrate the robustness of one HX-MS2 configuration (consisting of Trajan HDX automation technology, an Orbitrap Eclipse mass spectrometer and AutoHX software) on an extensive time-course analysis of phosphorylase B and an epitope analysis of single-domain antibodies (VHHs, nanobodies) specific to the receptor binding domain of SARS-CoV-2 spike protein.
Related Concept Videos
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
High-Resolution Mass Spectrometry (HRMS)
¹H NMR of Labile Protons: Deuterium (²H) Substitution
Mass Analyzers: Overview
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...