Challenges in Detecting Hydroxyl Radicals Generated in Water Droplets with Mass Spectrometry
Dong Xing1, Xufeng Gao1, Huan Chen1
1College of Chemistry, State Key Laboratory of Advanced Chemical Power Sources, Key Laboratory of Advanced Energy Materials Chemistry (Ministry of Education), Renewable Energy Conversion and Storage Centre, Tianjin Key Laboratory of Biosensing and Molecular Recognition, Frontiers Science Centre for New Organic Matter, Nankai University, Tianjin 300071, China.
Abstract:
Water is sprayed into the air using three distinct methods: (1) nanoelectrospray ionization, (2) a vibrating membrane nebulizer, and (3) a pneumatic nebulizer. The resulting droplets are analyzed by three different mass analyzers: (a) a linear ion trap mass analyzer on an LTQ-XL mass spectrometer, (b) the Velos Pro dual-pressure linear ion trap mass analyzer on an Orbitrap Elite mass spectrometer, and (c) the Orbitrap mass analyzer on the same Orbitrap Elite system. We searched for hydroxyl radical adducts with hydronium ions (OH•-H3O+) or reaction products with caffeine dissolved in water and with melatonin dissolved in water. These experiments were repeated in several different laboratories, and all results were the same. The oxidation products of caffeine and melatonin were not detected when using the Orbitrap mass analyzer having a much longer holding time in the ion trap (500 ms) but could be observed with reduced intensity at much shorter holding times (<10 ms). The signal of OH•-H3O+ was also significantly reduced when using the Velos Pro dual-pressure linear ion trap mass analyzer. These results suggest that ion signals from fragile radicals may be diminished or lost depending on the mass detection system and operating conditions employed, and there may be a risk of obtaining spurious results when using an Orbitrap mass spectrometer.
More Related Videos
09:59Laser-free Hydroxyl Radical Protein Footprinting to Perform Higher Order Structural Analysis of Proteins
Published on: June 4, 2021
07:38Enabling Real-Time Compensation in Fast Photochemical Oxidations of Proteins for the Determination of Protein Topography Changes
Published on: September 1, 2020
Related Concept Videos
High-Resolution Mass Spectrometry (HRMS)
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Alcohol Fragmentation
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometry: Overview
NMR Spectroscopy and Mass Spectrometry of Aldehydes and Ketones