Related Experiment Video
Updated: May 16, 2025

Author Spotlight: Unraveling the Impact of Mechanical Ventilation on Diaphragm Function and Patient Outcomes
Published on: November 3, 2023
A Study on the Diagnostic Accuracy of Tidal Volume-Diaphragmatic Contraction Velocity: A Novel Index for Weaning
Apostolos A Menis1,2, Vasiliki Tsolaki1, Maria E Papadonta1
1Intensive Care Unit, University Hospital of Larissa, Larissa, Greece.
Objectives:
Weaning failure from mechanical ventilation (MV) is primarily caused by increased respiratory load and decreased respiratory neuromuscular competency, leading to a rapid shallow breathing pattern. We hypothesized that the product of diaphragmatic contraction velocity (a sonographic estimate of respiratory load) and tidal volume (an estimate of breathing pattern), termed the volume-velocity index (VVI), may predict weaning outcomes.
Design:
The diagnostic accuracy of VVI (mL*cm/s) in predicting weaning outcomes was prospectively assessed, along with its relationship to indices of breathing effort, including esophageal pressure swings (ΔPes), the pressure-time product of esophageal pressure (PTPes), and maximal inspiratory pressure (MIP). A power analysis, informed by the results of an inception cohort, determined the required sample size for the validation cohort. Patients were enrolled through consecutive sampling. Weaning failure was defined as failure of the spontaneous breathing trial (SBT) or the need for MV within 48 hours.
Setting:
The study was conducted in a tertiary academic ICU.
Patients:
VVI was evaluated in critical care patients undergoing a SBT for the first time.
Interventions:
None.
Measurements And Main Results:
In the inception cohort ( n = 30), VVI was significantly higher in successful weaning compared to failures (764.76 [±432.61] vs. 278 [±183.66], p < 0.001). It correlated with ΔPes ( r = 0.74, R2 = 0.55), PTPes ( r = 0.76, R2 = 0.58), and MIP ( r = 0.75, R2 = 0.55) all p values less than 0.001. In the validation cohort ( n = 40), VVI was higher in successful weaning (840 [550, 1220] vs. 250 [225, 302.5], p < 0.001) and predicted weaning success with an area under the receiver operating characteristic of 0.92 (95% CI, 0.83-1).
Conclusions:
VVI effectively differentiates between weaning success and failure, shows a strong correlation with respiratory effort indices, and may enhance weaning protocols.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Volumes and Capacities