Related Experiment Video
Updated: May 16, 2025

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
Optical design and commissioning results of a constant-imaging-distance fixed-included-angle grating monochromator at
Lian Xue1, Zhongliang Li1, Junnan Liu1
1Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, People's Republic of China.
Abstract:
A constant-imaging-distance fixed-included-angle grating monochromator has been designed and constructed at the Shanghai Synchrotron Radiation Facility to expand the covered energy range of the X-ray test beamline. The design and first commissioning results are presented in this paper. Initial results reveal the good performance of this monochromator, with a photon energy resolving power estimated to be over 8000 at the krypton M-edge for high line density gratings and a -1st order diffraction efficiency of the grating better than 30% for low line density gratings.