Electric Field-Induced Dual-Gradient Heterojunction Diodes Toward Ultrasensitive Self-Powered Ionic Skin
Jiehan Lin1,2,3, Yongqi Mao4, Tianjiang Zheng4
1College of Chemistry and Molecular Sciences, Engineering Research Center of Natural Polymer-based Medical Materials in Hubei Province and Laboratory of Biomedical Polymers of Ministry of Education, Wuhan University, Wuhan, 430072, China.
Abstract:
The hydrogel ionic diode is regarded as a promising self-powered sensor, capable of harvesting energy from low-frequency stimuli human motions and converting it into electrical signals. However, the sensitivity of the reported conventional bilayer hydrogel ionic diodes are relatively low, due to the single heterojunction interface and high interface resistance, making it challenging to meet the demands of high-precision sensing. Here, a universal method for fabricating dual-gradient hydrogel ionic diodes without bilayer structure through the induction of anionic and cationic polymer gradient distribution via a direct current electric field is developed. Due to the dual-gradient distribution, numerous heterogeneous microstructures (i.e., microdiodes) with low interface resistance are formed in the bulk phase of hydrogel, and these series-connected microdiodes demonstrate a significantly increase in open circuit voltage in response to mechanical pressure. The dual-gradient hydrogel ionic diode exhibits ultra-high sensitivity (1247.3 mV/MPa) and ultralow detection limit (0.8 Pa), enabling the smart prosthetic hand to non-destructive grasp ultrasoft tofu. This work is expected to pave the way for novel high-precision self-powered sensors in intelligent wearable electronics.
More Related Videos
08:25Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
Published on: August 27, 2021
08:50Fabrication and Characterization of a Conformal Skin-like Electronic System for Quantitative, Cutaneous Wound Management
Published on: September 2, 2015
Related Concept Videos
P-N junction
Schottky Barrier Diode
Potentiometry: Membrane Electrodes
Biasing of P-N Junction
In equilibrium, no external voltage is applied across the p-n junction. The depletion region is formed at the junction interface due to the diffusion of carriers, which leaves behind charged dopants, acceptors on the p-side, and donors on the n-side. These immobile charges create an electric field that prevents further diffusion of carriers. The related energy band...
Diode: Reverse bias