Related Experiment Video
Updated: May 16, 2025

MRI and PET in Mouse Models of Myocardial Infarction
Published on: December 19, 2013
Myocardial Perfusion Imaging With PET: A Head-to-Head Comparison of 82Rubidium Versus 15O-water Tracers Using
Simon Winther1,2, Laust Dupont Rasmussen1,3, Salma Raghad Karim2,4
1Department of Cardiology (S.W., L.D.R., J.N.D., J.H.S., L.N., F.B.L., M.W., J.M.S., M.B.), Gødstrup Hospital, Herning, Denmark.
Background:
Myocardial perfusion imaging by positron emission tomography (PET) is recommended as a first-line test in stable patients with chest pain symptoms and as a selective second-line test after an abnormal coronary computed tomography angiography (CTA). It is, however, unknown whether the use of Rubidium-82 (82Rb) versus [15O]H2O (15O-water) affects the diagnostic performance in coronary artery disease (CAD). The aim of this study was to compare 82Rb-PET versus 15O-water-PET head-to-head for diagnosing obstructive CAD.
Methods:
The study included consecutive patients (n=1000) referred for CTA with symptoms suggestive of obstructive CAD. Patients with suspected stenosis based on CTA were referred for both 82Rb-PET, 15O-water-PET, and subsequently invasive coronary angiography (ICA), including 3-vessel fractional flow reserve and coronary flow reserve measurements.
Results:
In total, 196/270 (73%) patients with suspected stenosis on CTA completed 82Rb-PET, 15O-water-PET, and ICA. Myocardial blood flow measurements from 82Rb-PET and 15O-water-PET correlated strongly at rest (ρ, 0.62-0.69) but only moderately during hyperemia (ρ, 0.41-0.59). Only weak correlations were demonstrated between myocardial blood flow reserve by both PET tracers compared with ICA coronary flow reserve (ρ, 0.11-0.38). Hemodynamically obstructive CAD defined as ICA fractional flow reserve ≤0.80, was identified in 86/196 (44%) patients. Using predefined cutoffs, the diagnostic accuracies of 82Rb-PET versus 15O-water-PET were similar (sensitivity 69% [58-78%] versus 71% [60-80%], P=0.59; specificity 85% [76-91%] versus 77% [68-85%], P=0.12). Using ICA diameter stenoses >70% as a reference, only 48/196 (24%) patients had anatomically severe CAD, and 82Rb-PET and 15O-water-PET sensitivities increased to >85%.
Conclusions:
For detection of obstructive CAD by PET myocardial perfusion imaging, 82Rb versus 15O-water have similar diagnostic performance.
Registration:
URL: https://www.clinicaltrials.gov; Unique identifier: NCT04707859.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...