Impact of pullback speed on evaluation of lipid core plaque using near-infrared spectroscopy-intravascular ultrasound
Tetsuharu Kasahara1, Hideki Kitahara2, Kenta Takou1
1Department of Radiology, Chiba University Hospital, Chiba, Japan.
Abstract:
Near-infrared spectroscopy-intravascular ultrasound (NIRS-IVUS) can assess the amount of lipid core plaque, and the latest generation catheter allows for imaging at several different pullback speeds. The purpose of this study was to investigate the impact of pullback speed on evaluation of lipid core plaque using the latest generation NIRS-IVUS catheter. Patients with coronary artery disease who underwent coronary angiography or percutaneous coronary intervention with NIRS-IVUS examination at 2 different pullback speeds (0.5 and 2.0 mm/sec) for the same vessel were enrolled. The values of lipid core burden index (LCBI) and maxLCBI4mm were compared between the images recorded with pullback speeds of 0.5 and 2.0 mm/sec, and match or mismatch of the location where maxLCBI4mm was detected was investigated. In a total of 286 NIRS-IVUS image sets, the location of maxLCBI4mm measured at 0.5 and 2.0 mm/sec was mismatched in 81 (28.3%) image sets. In comparison by vessel type, 20.8% were mismatched in LAD, 31.1% in LCx, and 37.8% in RCA (p = 0.023). In 205 image sets with matched maxLCBI4mm location, the maxLCBI4mm value at 2.0 mm/sec was significantly greater compared with that at 0.5 mm/sec (348.0 vs. 302.0 in median, p < 0.001). In a substantial proportion of patients, the location of maxLCBI4mm values measured at 0.5 and 2.0 mm/sec was mismatched. In the image sets with matched maxLCBI4mm location, the maxLCBI4mm value at 2.0 mm/sec was significantly greater compared with that at 0.5 mm/sec. These results should be noted when applying the cut-off values of maxLCBI4mm recorded at 2.0 mm/sec.
More Related Videos
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
06:18Intravascular Ultrasound Image-Based Finite Element Modeling Approach for Quantifying In Vivo Mechanical Properties of Human Coronary Artery
Published on: December 6, 2024
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Imaging Studies VII: Vascular Imaging