An airborne CH4 sensor with temperature compensation based on a miniature optical structure for natural gas pipeline
Guolin Li1, Haoran Yuan1, Yingjie Zhao1
1The Shandong Provincial Engineering Research Center of Intelligent Sensing and Measurement and Control Technology, College of Control Science & Engineering, China University of Petroleum (East China), Qingdao 266580, PR China.
Abstract:
Pipeline transport plays an important role in the exploration and transmission of natural gas. An airborne near-infrared (NIR) methane (CH4) sensor has been developed to analyze CH4 leakage in the pipeline transport process based on the tunable diode laser absorption spectroscopy combined with wavelength modulation spectroscopy (WMS-TDLAS) technology relying on the high efficiency and convenience of unmanned aerial vehicles (UAVs). A laser diode in the form of an ultra-compact 8-pin package with a center wavelength of 1653.7 nm and an independently-designed miniature optical structure with an optical path length of 36 cm are adopted, which greatly reduces the size of the sensor. In order to improve the measurement accuracy, a temperature compensation link is designed to minimize the influence of temperature changes on the measured value. The original second harmonic signal is denoised by the variational mode decomposition algorithm optimized by Genghis Khan shark optimizer algorithm (GKSO-VMD), and the Bi-directional long short-term memory GKSO-BiLSTM algorithm is used for CH4 concentration inversion. The measured and real concentration values of the sensor are closely related, with a correlation coefficient (R2) of 0.9996. The response time experiment demonstrates that the response time is approximately 6 s. The great stability of the sensor is confirmed by the long-term stability experiment. According to the Allan-Werle deviation, it is estimated that the sensor has a limit of detection (LoD) 613 ppb with an integration time of 230 s. Therefore, an effective analysis method is proposed for CH4 leakage analysis during natural gas pipeline transport.
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-III
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...