Experimental study on flexural behavior of bonded steel-concrete composite beams
Junhu Shao1,2, Haijun Jiang3,4, Lei Zhang3,5
1School of Civil Engineering, Southwest Jiaotong University, Chengdu, 610031, China. shaojunhu@cdu.edu.cn.
Abstract:
To address the limitations of mechanical shear connectors, adhesives are used in this research as shear connectors of steel-concrete composite beams (SCCBs). Several groups of bending tests were conducted to compare the flexural behavior of bonded and mechanical SCCBs. Moreover, the results show that the failure modes of the bonded SCCBs mainly include yielding of the bottom flange of the I-beam and the cracking of the concrete bottom surface, local detachment between the two bonding surfaces and the crushing of the concrete slab at the top surface. The rigidity of the bonded SCCB is higher than that of the mechanical one. In addition, the ultimate load of the bonded SCCB connected by 6 mm thick epoxy resin is the highest, which is about 16.8% higher than that of mechanical one. Furthermore, increasing the adhesive layer's thickness can improve the adhesive performance to a certain extent. Thus, it is suggested that the adhesive thickness should exceed 4 mm, and 6 mm is the optimal. In addition, as local detachment of the adhesive layer occurred in this test, further research can be carried out to avoid such damage.
More Related Videos
05:26Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
Related Concept Videos
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Design of Prismatic Beams for Bending
Relation Between Tensile Strength and Compressive Strength of Concrete