Aims:
Patients with acute decompensated advanced heart failure requiring left ventricular assist device (LVAD) implantation often experience progressive cardiac function deterioration, negatively impacting surgical outcomes. This study aimed to assess the efficacy of different microaxial flow pump (mAFP) support devices (Impella®) in achieving optimal left ventricular unloading for preconditioning and facilitating definitive treatment in this high-risk patient cohort.
Methods And Results:
A retrospective analysis was conducted across 19 high-volume European centres. The study population included patients transitioning from temporary to durable circulatory support over a 7.5-year period, with a median follow-up of 1 year. Patients were categorized based on mAFP support capacity: those receiving high-flow support (>5 L/min, '5+') and those with lower-flow support (3.5 L/min, 'CP'). Patients who were initially treated with CP but subsequently upgraded to 5+ support were classified in the 5+ group. Demographic and clinical characteristics, mobilization, right heart function, and organ dysfunction outcomes were analysed. A total of 339 patients received preoperative mAFP support prior to LVAD implantation. The 5+ group comprised 247 patients (73%), including 38 patients who were upgraded from CP, while the CP group included 92 patients (27%). Baseline demographic and clinical characteristics were comparable between groups, except for mobilization status, which showed significant differences (P < 0.001). Patients in the 5+ group achieved higher rates of full and partial mobilization compared to the CP group. Extracorporeal life support (ECLS) was more frequently required in the CP group than in the 5+ group (40.5% vs. 33.8%; P < 0.001). Additionally, right ventricular assist device (RVAD) implantation was significantly more common in the CP group (29.2% vs. 18.2%; P = 0.026). Patients in the 5+ group demonstrated greater reductions in both vasoactive inotropic scores (P = 0.006) and inotropic scores (P = 0.008). Furthermore, liver dysfunction (P = 0.016), renal failure (P = 0.041), and the need for dialysis (P = 0.013) were significantly more prevalent in the CP group. There were no significant differences between the two groups in terms of LVAD operative duration (P = 0.637) or cardiopulmonary bypass time (P = 0.408).
Conclusions:
High-flow mAFP devices (+5) provided superior haemodynamic support, enhanced left ventricular unloading, and reduced dependence on catecholamines compared to lower-flow CP devices. These improvements were associated with lower rates of right ventricular failure, renal dysfunction, and liver injury. However, no statistically significant difference was observed between mAFP groups regarding 30-day mortality rates.
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Pivot Bearings
A pivot bearing is a specialized type of bearing designed to support axial loads on a rotating shaft. The bearing surface, or the pivot, is positioned at the end of a shaft to support the axial thrust. The pivot may...
Design of Transmission Shafts
Thin-Walled Hollow Shafts
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
Multiple Pipe Systems
Series Configuration