Related Experiment Video
Updated: Jun 15, 2026

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Left atrial strain by vendor-neutral echocardiography software in healthy subjects: vendor comparisons and associated
Tiffany Dong1, Aro Daniela Arockiam1, Ankit Agrawal1
1Section of Cardiovascular Imaging, Department of Cardiovascular Medicine, Sydell and Arnold Miller Heart, Vascular, and Thoracic Institute, Cleveland Clinic, 9500 Euclid Avenue, Main Campus, J1-5, Cleveland, OH 44195, USA.
Aims:
Left atrial strains [reservoir (LASr), conduit (LAScd), and contractile (LASct)] are increasingly utilized, primarily in the areas of heart failure and valvulopathy. Commercially available software to measure strain are marketed as imaging machine vendor independent, although the normal ranges of their performance and external validation studies are lacking. We evaluated and compared LAS values, reference ranges, and associated factors using contemporary strain software.
Methods And Results:
Healthy subjects (n = 100) undergoing transthoracic echocardiography during January to April 2023 were studied, with equal number by age groups, sex, and GE vs. Philips equipment. LASs were quantified using TomTec version 51.02 (AutoStrain LA), EchoPAC version 206 (AFILA), velocity vector imaging (VVI) version 2.00, and Epsilon version 5.0.2.11295 software. Means and lower limits of normal [95% confidence interval (CI)] of LASr (%) were 44.1 (41.9, 46.3) and 30.3 (26.4, 34.1) for TomTec; 34.8 (33.6, 36.0) and 26.3 (24.2, 28.4) for EchoPAC (on GE scans only); 42.5 (40.2, 44.8) and 28.4 (24.4, 32.4) for VVI; and 37.0 (34.9, 39.1) and 25.2 (21.5, 28.8) for Epsilon. Factors significantly associated with variability in LASr measurements and their beta-coefficients (95% CI) were age -2.37 (-3.41, -1.33) per 10 years, EchoPAC (vs. TomTec) -9.63 (-12.75, -6.51), and Epsilon (vs. TomTec) -7.04 (-9.40, -4.67). Reference ranges and factors significantly associated with LAScd and LASct were reported. LAS measurements and normal ranges by strain software and associated clinical and echocardiographic factors were determined.
Conclusion:
EchoPAC and Epsilon have lower magnitude mean LAS values compared with TomTec and VVI, and all software were vendor neutral except EchoPAC.
More Related Videos
06:34Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Heart Failure III: Clinical Manifestations
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Issues And Trends In Healthcare Delivery System
Cost Containment
Payment for healthcare services has historically promoted adoption of costly and often unnecessary or inefficient...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...