Related Experiment Video
Updated: May 6, 2026

Method and Instrumented Fixture for Femoral Fracture Testing in a Sideways Fall-on-the-Hip Position
Published on: August 17, 2017
Validity and Agreement of a Portable Dynamometer in Evaluating Hip Strength and Rate of Torque Development: Influence
Sungwan Kim1, Takhyun Yoo1, Julie P Burland1
1Kinesiology University of Connecticut.
Background:
Portable dynamometers (PD) are widely used to assess hip muscle strength; however, few studies have explored their validity and agreement when evaluating the rate of torque development (RTD) of hip muscles, particularly with different fixation methods.
Hypothesis/Purpose:
The purpose of this study was to determine the validity and agreement of isometric hip strength and RTD using the PD with two fixation methods: placing the PD on the body (PDpush) or a treatment table (PDpull), compared to an isokinetic dynamometer (IKD). It was hypothesized that an PD would be a valid tool for assessing hip strength and RTD, with PDpull demonstrating strong validity and PDpush showing moderate validity; and its assessments would yield higher values than those obtained from IKD.
Study Design:
Cross-sectional study.
Methods:
Twenty healthy, physically active individuals (10 females and 10 males) were included in this study. Hip abduction and extension strength (peak torque) and RTD (early phase: RTD0-100 ms and late phase: RTD100-200 ms) were assessed using PDpush, PDpull, and an IKD.
Results:
Moderate-to-strong correlations were found between PD (both PDpush and PDpull) and IKD for all hip strength (r=0.46-0.73; p<0.05) and RTD (r=0.45-0.73, ρ=0.80; p<0.05) measures. PDpull demonstrated strong correlations for hip abduction RTD0-100 ms and hip extension strength and RTD100-200 ms (r=0.70-0.73; p<0.001), whereas PDpush showed moderate correlations (r=0.45-0.58; p<0.05). Bland-Altman plots with mean differences ± 95% limits of agreement indicated that the PDpush method overestimated all hip abduction and extension strength and RTD as compared to IKD. The PDpull method overestimated hip abduction and extension strength but had mixed results for RTD, either underestimating hip abduction RTD while overestimating hip extension RTD.
Conclusion:
The PD is valid tool for evaluating hip strength and RTD, with PDpull offering strong validity for certain measures; however, PD measurements did not agree with the absolute values obtained from IKD.
Level Of Evidence:
Level 3.
More Related Videos
12:59Improving Strength, Power, Muscle Aerobic Capacity, and Glucose Tolerance through Short-term Progressive Strength Training Among Elderly People
Published on: July 5, 2017
07:30Muscle Imbalances: Testing and Training Functional Eccentric Hamstring Strength in Athletic Populations
Published on: May 1, 2018
Related Concept Videos
Indeterminate Structure
Transmission Shafts: Problem Solving
Next, use bending moment diagrams for the shaft to...
Turbine-Governor Control
Flow Table Test
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
Non-destructive Tests for Concrete Strength
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used...