Related Experiment Video
Updated: May 16, 2025

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
T1 Relaxation-Enhanced Steady-State Acquisition With Radial k-Space Sampling: A Novel Family of Pulse Sequences for
Ruoxun Zi1, Robert R Edelman, Christoph Maier
1Bernard and Irene Schwartz Center for Biosmedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY (R.Z., C.M., R.L., D.K.S., K.T.B.); Center for Advanced Imaging Innovation and Research (CAI R), Department of Radiology, New York University Grossman School of Medicine, New York, NY (R.Z., C.M., R.L., D.K.S., K.T.B.); Radiology, NorthShore University HealthSystem, Evanston, IL (R.R.E.); Feinberg School of Medicine, Northwestern University, Evanston, IL (R.R.E.); and Siemens Medical Solutions, New York, NY (M.K.).
Objectives:
Magnetization-prepared rapid gradient-echo (MP-RAGE) sequences are routinely acquired for brain exams, providing high conspicuity for enhancing lesions. Vessels, however, also appear bright, which can complicate the detection of small lesions. T1RESS (T1 relaxation-enhanced steady-state) sequences have been proposed as an alternative to MP-RAGE, offering improved lesion conspicuity and suppression of blood vessels. This work aims to evaluate the performance of radial T1RESS variants for motion-robust contrast-enhanced brain MRI.
Materials And Methods:
Radial stack-of-stars sampling was implemented for steady-state free-precession-based rapid T1RESS acquisition with saturation recovery preparation. Three variants were developed using a balanced steady-state free-precession readout (bT1RESS), an unbalanced fast imaging steady precession (FISP) readout (uT1RESS-FISP), and an unbalanced reversed FISP readout (uT1RESS-PSIF). Image contrast was evaluated in numerical simulations and phantom experiments. The motion robustness of radial T1RESS was demonstrated with a motion phantom. Four patients and six healthy volunteers were scanned at 3 T and 0.55 T. Extensions were developed combining T1RESS with GRASP for dynamic imaging, with GRAPPA for accelerated scans, and with Dixon for fat/water separation.
Results:
In simulations and phantom scans, uT1RESS-FISP provided higher signal intensity for regions with lower T1 values (<500 ms) compared with MP-RAGE. In motion experiments, radial uT1RESS-FISP showed fewer artifacts than MP-RAGE and Cartesian uT1RESS-FISP. In patients, both unbalanced uT1RESS variants provided higher lesion conspicuity than MP-RAGE. Blood vessels appeared bright with MP-RAGE, gray with uT1RESS-FISP, and dark with uT1RESS-PSIF. At 0.55 T, bT1RESS provided high signal-to-noise ratio T1-weighted images without banding artifacts. Lastly, dynamic T1RESS images with a temporal resolution of 10.14 seconds/frame were generated using the GRASP algorithm.
Conclusions:
Radial T1RESS sequences offer improved lesion conspicuity and motion robustness and enable dynamic imaging for contrast-enhanced brain MRI. Both uT1RESS variants showed higher tumor-to-brain contrast than MP-RAGE and may find application as alternative techniques for imaging uncooperative patients with small brain lesions.