Related Experiment Video
Updated: May 16, 2025

In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
Computed Tomography Scan Detection of Intra-Articular Air in the Ankle Joint: A Cadaveric Study
J Scott Donoughe1, Daniel Wido2, Kyle Mombell3
1Department of Orthopaedic Surgery, Naval Medical Center Camp Lejeune, Camp Lejeune, NC 28547, United States.
Introduction:
The diagnosis of traumatic arthrotomy is often accomplished using the saline load test. The introduction of large volumes of saline into the joint is uncomfortable for the patient and has been reported to have low sensitivity and specificity. Computed tomography (CT) scan has been previously validated as a fast and reliable method of detecting free air in the knee joint. The primary objective of this study was to evaluate the use of CT scan for the detection of intra-articular free air in the ankle joint.
Methods:
Eighteen fresh-frozen cadaver distal lower extremities were thawed, and then CT scans were obtained at their baseline harvested state. The tibiotalar joint was injected with 0.05cc free air, and then repeat CT scans of each specimen were obtained. Specimens with instrumentation, intra-articular air, or ambiguous free air prior to intervention were excluded from the study. Scans were performed from the mid leg through the entire foot at institution standard radiation dose (120 kV, 170 mA) and a slice thickness of 0.6 mm. Images were anonymized, randomized, and sent to 4 reviewers (2 orthopedic surgeons, 1 musculoskeletal radiologist, and 1 radiology resident) for evaluation of free air. Sensitivity and specificity of CT to detect free air were calculated, and Fleiss's Kappa coefficient was used to determine interobserver reliability.
Results:
The sensitivity and specificity of CT to detect free air in cadaver ankles was 100%. Twenty-two CT scans (11 natural state and 11 with simulated air arthrotomies) were correctly identified for the presence or absence of intra-articular free air by all reviewers with kappa coefficient 1.0 (complete agreement).
Conclusions:
Computed tomography is a fast, reproducible method for detecting small volumes of free air in the ankle and may offer clinical benefit in evaluation of traumatic arthrotomy of the ankle.
More Related Videos
07:24Autologous Microfractured and Purified Adipose Tissue for Arthroscopic Management of Osteochondral Lesions of the Talus
Published on: January 23, 2018
07:10Micro-Computed Tomography Analysis of the Knee in Aged Dunkin-Hartley Guinea Pigs after Intra Articular Injection
Published on: August 2, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Ankle Joint
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...