Related Experiment Video
Updated: Jun 27, 2026

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
On the PTV homogeneity objective in the era of photon advanced dose calculation algorithms: Bridging robust and
Diego Jurado-Bruggeman1, Agnes Angerud2, Albin Fredriksson2
1Medical Physics and Radiation Protection Department, Institut Català d'Oncologia, Girona, Spain; Radiation Oncology and Medical Physics of Girona Group, Girona Biomedical Research Institute (IDIBGI), Girona, Spain.
Aim:
The planning target volume (PTV) homogeneity objective was developed for previous-generation dose calculation algorithms. Advanced algorithms report doses to medium-in-medium (Dm,m) and their values depend on the medium considered, breaking the link between uniform irradiation and dose homogeneity. This work revises the PTV homogeneity objective when high-density heterogeneities are involved. We evaluated robust against PTV-based planning, and a dose reporting method that removes composition dependencies to express doses to muscle in muscle-like medium (Dmuscle,muscle*).
Methods:
Four cases featuring bone or metal within the PTV were selected and planned in RayStation with Monte Carlo. Three plans were created for each case: robust optimization for Dm,m (Robust-Dm,m), and PTV-based optimization for Dm,m (PTV-Dm,m) and Dmuscle,muscle* (PTV-Dmuscle,muscle*). The plans were reported in Dm,m and Dmuscle,muscle*, and their dosimetric parameters, robustness, complexities, and optimization times were assessed.
Results:
Robust-Dm,m and PTV-Dmuscle,muscle* plans presented similar Dm,m distributions with inhomogeneous PTV doses due to cold spots in high-density regions. PTV-Dm,m plans achieved homogeneous PTV doses but required local fluence compensations that impaired robustness, with significant hot spots, and increased complexity. Robust optimization was 7 to 11 times slower. Reporting in Dmuscle,muscle* restored consistency between PTV-based and robust evaluations.
Conclusions:
Robust optimization proves that PTV homogeneity should not be prioritized when advanced algorithms reporting Dm,m are used with high-density heterogeneities. PTV-Dmuscle,muscle* optimization offers a practical alternative for maintaining PTV-based planning and the PTV homogeneity objective while ensuring consistency with robust optimization. Dmuscle,muscle* reporting simplifies plan evaluation and aligns with clinical practice, facilitating decision-making in treatment planning.
More Related Videos
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...