Enhancing the Separation and Quantification of Perfluoroalkyl Substances Using Polymeric Ionic Liquid Sorbents in
Aghogho A Olomukoro1,2,3, Derek R Eitzmann4, Jared L Anderson4
1Department of Chemistry and Biochemistry, The University of Toledo, Toledo, Ohio 43606, United States.
Abstract:
The preconcentration and isolation of per- and polyfluoroalkyl substances (PFAS) remain challenging due to their varying chain lengths and diverse headgroup chemical functionalities. These substances are persistent and occur in the environment at low parts-per-trillion concentration levels, necessitating the use of efficient and selective sorbents that can enhance their preconcentration from the targeted sample prior to instrumental analysis. This study, for the first time, evaluates the use of a polymeric ionic liquid (PIL) consisting of 1-(9-carboxy-nonyl)-3-vinylimidazolium bromide [C9COOHVim+] [Br-] ionic liquid (IL) monomer and 1,12-di(3-vinylimidazolium)dodecane bromide ([C12(Vim+)2]2[Br-]) IL cross-linker for the simultaneous separation and preconcentration of 15 anionic PFAS. The PIL was immobilized on a thin film microextraction device to improve preconcentration, extraction, and desorption kinetics. The addition of competing anions to the desorption solution was critical to ensure the quantitative desorption of the anionic PFAS by an ion exchange mechanism. Partition coefficient calculations revealed a balanced extraction coverage for short- and long-chain PFAS in ultrapure water, while in solutions at high ionic strength, short-chain PFAS tend to display less affinity for the sorbent compared to long-chain PFAS. Kinetic studies showed that less hydrophobic PFAS (perfluorobutanoic acid (PFBA)-perfluorohexanoic acid (PFHxA)) reached equilibrium faster and the extraction followed a pseudo-second order model with r2 values up to 0.9874. The applicability of the PIL-thin film microextraction (TFME) device for quantitative analysis was demonstrated by a calibration curve in a concentration range from 1 ng L-1 to 2500 ng L-1, which showed good accuracy (70-130%), precision (<20%), and limits of quantification from 1 ng L-1 to 50 ng L-1.
More Related Videos
07:06Investigating Long-Distance Transport of Perfluoroalkyl Acids in Wheat via a Split-Root Exposure Technique
Published on: September 28, 2022
12:05Preparation of Hydrophobic Metal-Organic Frameworks via Plasma Enhanced Chemical Vapor Deposition of Perfluoroalkanes for the Removal of Ammonia
Published on: October 10, 2013
Related Concept Videos
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion-Exchange Chromatography
Analyte Adsorption and Distribution
