Related Experiment Video
Updated: May 15, 2025

07:03
In Situ Measurement of Vacuum Window Birefringence using 25Mg+ Fluorescence
Published on: June 13, 2020
3.8K
Erratum: Self-Consistent Extraction of Spectroscopic Bounds on Light New Physics [Phys. Rev. Lett. 130, 121801
Physical Review Letters
|April 7, 2025
Abstract:
This corrects the article DOI: 10.1103/PhysRevLett.130.121801.
Related Concept Videos
Emission Spectra
49.3K
When solids, liquids, or condensed gases are heated sufficiently, they radiate some of the excess energy as light. Photons produced in this manner have a range of energies, and thereby produce a continuous spectrum in which an unbroken series of wavelengths is present.
49.3K
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
1.1K
A covalently bonded heteronuclear diatomic molecule can be modeled as two vibrating masses connected by a spring. The vibrational frequency of the bond can be expressed using an equation derived from Hooke's law, which describes how the force applied to stretch or compress a spring is proportional to the displacement of the spring. In this case, the atoms behave like masses, and the bond acts like a spring.
According to Hooke's law, the vibrational frequency is directly proportional to...
According to Hooke's law, the vibrational frequency is directly proportional to...
1.1K
Atomic Absorption Spectroscopy: Radiation and Light Sources
276
Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
276
The Pauli Exclusion Principle
33.6K
The arrangement of electrons in the orbitals of an atom is called its electron configuration. We describe an electron configuration with a symbol that contains three pieces of information:
33.6K
¹H NMR: Interpreting Distorted and Overlapping Signals
932
Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
932
UV–Vis Spectroscopy: Molecular Electronic Transitions
1.3K
In Ultraviolet–Visible (UV–Vis) spectroscopy, the absorption of electromagnetic radiation is used to probe the electronic structure of molecules. This technique provides insights into molecular electronic transitions, particularly the movement of electrons between different molecular orbitals. Radiation is absorbed if the energy of the electromagnetic radiation passing through the molecule is precisely equal to the energy difference between the excited and ground states. During this...
1.3K

