Detection of fluid responsiveness by changes of perfusion index and pleth-variability index during passive leg
Simon Rauch1,2, Paolo Mario Seraglio1, Tomas Dal Cappello2
1Department of Anesthesia and Intensive Care Medicine, "F. Tappeiner" Hospital Merano, 39012, Merano, Italy.
Abstract:
Predicting fluid responsiveness is crucial in treating circulatory failure, as only about half of patients benefit from volume expansion by increasing cardiac output (CO). Dynamic tests like passive leg raising (PLR) are preferred over static parameters. While PLR reliably predicts fluid responsiveness, it typically requires invasive measurement of stroke volume (SV) or CO. The perfusion index (PI) and pleth variability index (PVI) are non-invasive metrics derived from oxygen saturation signals. PI has been shown to correlate with SV, and PVI has predicted fluid responsiveness in mechanically ventilated patients, but their role in spontaneously breathing patients remains unclear. This study aimed to assess whether PI and PVI could predict fluid responsiveness in post-surgical, spontaneously breathing patients during a PLR test. The hypothesis was that PI would increase and PVI would decrease in fluid responders. The prospective study included spontaneously breathing patients after major abdominal surgery in the ICU of Merano Hospital, Italy. SV and CO were measured using the FloTrac™ system, and PI and PVI were assessed using the Radical 7® monitor. Patients were considered responders if SV increased by ≥ 10% during the PLR test. Of the 47 patients enrolled, 23 (48.9%) were fluid responders. The percentage change in PI from baseline to 60 s into the PLR test was + 41.2% in responders and + 11.3% in non-responders. A PI increase of ≥ 23% predicted responders with 70% sensitivity and 75% specificity, with an area under the ROC curve of 0.74. Twenty-two patients (47%) were inside the grey zone. PVI did not differ significantly between groups. In conclusion, PI could be a helpful non-invasive tool for predicting fluid responsiveness during a PLR test in spontaneously breathing patients, though its diagnostic accuracy appears to be moderate.
More Related Videos
04:44Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
04:34A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
Published on: May 31, 2019
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessing Blood pressure in the Leg
Preparation:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: