Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
The effect of software and hardware version on Apple Watch activity measurement: A secondary analysis of the COVFIT
Shelby L Sturrock1, Rahim Moineddin2, Dionne Gesink1
1Division of Epidemiology, Dalla Lana School of Public Health, University of Toronto.
Abstract:
The objective of this study was to estimate the impact of software and hardware version on Apple Watch activity measurement using data from the COVFIT retrospective cohort study. We estimated the impact of software and hardware versions on activity measurement by comparing daily active calories and daily exercise minutes in the 7 days before and 7 days after upgrading from watchOS 5 to 6, 6 to 7, 7 to 8, 8 to 9 or between two hardware versions. For each transition, we fit mixed effect negative binomial regression models to estimate the effect of the upgrade on daily (a) exercise minutes and (b) active calories, overall and stratified by sex, with and without adjusting for weekday. We also calculated and plotted the mean person-level change in average activity levels between the two weeks. As a control, we repeated the entire analysis comparing activity data two weeks before vs. one week before each upgrade. 253 participants contributed data about at least one transition (software = 250, hardware = 74). Hardware upgrades were not associated with either outcome; however, some software upgrades were. Upgrading from watchOS 7 to 8 was associated with a large, statistically significant increase in daily exercise minutes (unadjusted rate ratio (RR) = 1.13, 95% CI: 1.06, 1.20). WatchOS 6 to 7 and 8 to 9 transitions were associated with statistically significant decreases in daily exercise minutes (6 to 7: unadjusted RR = 0.92, 95% CI: 0.86, 0.99; 8 to 9: unadjusted RR = 0.91, 95% CI: 0.86, 0.96) and active calories (6 to 7: RR = 0.96, 95% CI: 0.94, 0.99); 8 to 9: RR = 0.97, 95% CI: 0.94, 0.99). There was no significant change in either outcome during in the two-week control period for most transitions. Differences in software version over time or between people may confound physical activity analyses using Apple Watch data.
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Measurement of Blood Pressure
Factors Affecting Activity Coefficient
The activity coefficient value for an ion is close to one when the solution has almost zero ionic strength, i.e., when the solution shows close to ideal behavior. As the ionic strength of the solution increases from 0 to 0.1 mol/L, a...
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring pulse