Appropriate compression values for the transtibial prosthesis using the AERO prosthetic liner
Yusuke Miyata1, Yasmin Nutchamlong1, Gary Guerra2
1Sirindhorn School of Prosthetics and Orthotics, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand.
Abstract:
Positive model rectification is a key factor in providing a comfortable and successful transtibial prosthetic socket fitting. This study aimed to assess whether a 4% compression value in 3- and 5-mm thickness affordable ethylene-vinyl acetate roll-on (AERO) liners yields acceptable comfort and pressure distribution for transtibial prosthetic users. Stump socks were used to adjust volume in the fitting process with a socket compressed to 4%, and pressure data were collected using 6 force-sensing resistor (FSR400) sensors placed in areas sensitive and tolerant to pressure. Peak pressure was collected from 40 steps, and pressure uniformity was calculated using the coefficient of variation in 2-min walking on the treadmill. The socket comfort score was collected after the trial. Appropriate compression values, pressure distribution, and socket comfort score were analyzed using Wilcoxon signed-rank tests, and effect size was determined using Cliff's delta. The study found that a 4.95% compression was optimal for a 3-mm thickness liner, whereas a 4.5% compression suited a 5-mm liner better for comfort. Moreover, the study observed a small similarity in pressure distribution between liners, as indicated by Cliff's delta, with the 5-mm liner possibly providing more even pressure because of its thickness. Despite being made of the same material, liners with different thicknesses distribute pressure differently. Therefore, this study suggests that a 4% universal compression value in the affordable ethylene-vinyl acetate roll-on liner may be effective for use in a clinical setting. Future studies should include more participants to identify the appropriate compression for a variety of residual limbs.
More Related Videos
08:08Oscillation and Reaction Board Techniques for Estimating Inertial Properties of a Below-knee Prosthesis
Published on: May 8, 2014
11:16Engineering Platform and Experimental Protocol for Design and Evaluation of a Neurally-controlled Powered Transfemoral Prosthesis
Published on: July 22, 2014
Related Concept Videos
Ankle Joint
Wedges
Consider using a wedge to lift a heavy slab. Here, the wedge functions by converting the applied force into a much larger force directed almost perpendicular to the initial force. This...
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Angle of Twist - Elastic Range