Abstract:
The simultaneous detection of multiple microRNAs (miRNAs) is critical for advancing precise disease diagnosis and treatment strategies. Herein, we introduce a novel method for the sensitive detection of multiple miRNAs using inductively coupled plasma mass spectrometry (ICP-MS), based on a platinum group element-bridged DNAzyme dual-walker amplification system. Upon binding to target miRNAs, the terminal of DNAzyme is released, triggering two DNAzyme-mediated ribonucleotide hydrolysis walking processes driven by Mg2+. These DNAzyme-walking sequences are recycled, enabling the continuous cleavage of substrate strands. After magnetic separation, the generated element pairs are quantified by mass spectrometry, enabling simultaneous and highly sensitive detection of multiple miRNAs. The method demonstrates a linear detection range from 5 fM to 10 pM with detection limits of 1.8 fM for miRNA-21, 1.1 fM for miRNA-199a, and 1.5 fM for miRNA-499, respectively.Furthermore, the approach exhibits remarkable specificity, making it suitable for detecting miRNAs in human serum. By demonstrating such a high sensitivity and specificity, this DNA walker-based sensing strategy holds significant potential for the development of versatile platforms to detect other miRNAs at varying expression levels.
Related Concept Videos
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Mass Analyzers: Common Types
Matrix-Assisted Laser Desorption Ionization (MALDI)
The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix material. The...