Related Experiment Video
Updated: May 15, 2025

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Accuracy of Smartwatch Pulse Oximetry Measurements in Hospitalized Patients With Coronavirus Disease 2019
Kevin Rajakariar1,2, Paul Buntine3,4, Andrew Ghaly1
1Department of Cardiology, Eastern Health, Melbourne, Victoria, Australia.
Objective:
To assess the ability of 2 commercially available smartwatches to accurately detect clinically significant hypoxia in patients hospitalized with coronavirus-19 (COVID-19).
Patients And Methods:
A prospective multicenter validation study was performed from November 1, 2021, to August 31, 2022, assessing the Apple Watch Series 7 and Withings ScanWatch inbuilt pulse oximetry, against simultaneous ward-based oximetry as the reference standard. Patients hospitalized with active COVID-19 infection not requiring intensive care admission were recruited.
Results:
A total of 750 smartwatch pulse oximetry measurements and 400 ward oximetry readings were successfully obtained from 200 patients (male 54%, age 66±18 years). For the detection of clinically significant hypoxia, the Apple Watch had a sensitivity and specificity of 34.8% and 97.5%, respectively with a positive predictive value of 78.1% and negative predictive value of 85.6%. The Withings ScanWatch had a sensitivity and specificity of 68.5% and 80.8%, respectively with a positive predictive value of 44.7% and negative predictive value of 91.9%. The overall accuracy was 84.9% for the Apple Watch and 78.5% for the Withings ScanWatch. The Spearman rank correlation coefficients reported a moderate correlation to ward-based photoplethysmography (Apple: rs=0.61; Withings: rs=0.51, both P<.01).
Conclusion:
Although smartwatches are able to provide SpO2 readings, their overall accuracy may not be sufficient to replace the standard photoplethysmography technology in detecting hypoxia in patients with COVID-19.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring pulse
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: