Fabrication of Compressed Hosiery and Measurement of its Pressure Characteristic Exerted on the Lower Limbs
Published on: May 27, 2020
Effects of Forearm Bandaging Technique, Muscle Contraction, and Additional Compression Pad Use on Sub-Bandage
Elif Sakizli Erdal1, Miray Haspolat2, Burak Erturk2
1Department of Physiotherapy and Rehabilitation, Kırıkkale University Faculty of Health Sciences, Kırıkkale, Türkiye.
Abstract:
Background: This study aimed to evaluate the effects of forearm bandaging techniques, muscle contraction, and additional compression pad use on sub-bandage pressure. Methods and Results: Thirty-one individuals (26 females, 5 males) with no chronic or lymphatic-related conditions participated in the study. Sub-bandage pressure was measured using the Kikuhime device, with a standardized protocol applied to the wrist extensor muscle belly. Participants were evaluated under rest and wrist extension conditions using two bandaging techniques: spiral and figure-of-eight. Variations included single and double layers, 1/2 and 1/3 overlaps, and the presence or absence of additional compression pads. Certified physiotherapists trained performed all bandaging applications using short-stretch compression materials. The figure-of-eight wrapping technique consistently produced significantly higher sub-bandage pressures compared to the spiral technique in all conditions. Double bandaging generated 1.4 times more pressure than single-layer applications, while 1/3 overlap resulted in greater pressure than 1/2 overlap. The addition of compression pads increased resting pressure by approximately 5 mmHg, and wrist extension further augmented pressure by 4-8 mmHg. The highest pressures were observed with the figure-of-eight technique, double bandaging, and 1/3 overlap combined (p < 0.05). Conclusions: These findings highlight the critical role of forearm bandaging technique, layering, and additional materials in determining sub-bandage pressure.
More Related Videos
06:51Author Spotlight: Development of a Minimally Invasive Large-Animal Model for Reliable and Reproducible Cardiovascular Research
Published on: October 20, 2023
09:24O-Ring Aortic Banding Versus Traditional Transverse Aortic Constriction for Modeling Pressure Overload-Induced Cardiac Hypertrophy
Published on: October 6, 2022
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure in the Leg
Preparation: