Related Experiment Video
Updated: May 15, 2025

A Novel Tenorrhaphy Suture Technique with Tissue Engineered Collagen Graft to Repair Large Tendon Defects
Published on: December 10, 2021
Failed Loop Endobutton Acromioclavicular Joint Reconstruction Treated with Duo Figure of 8 FiberTape Augmented
Saurabh Singh1, Sushit Kumar Sonu1, Rahul Patel1
1Department of Orthopedics, Institute of Medical Sciences, Banaras Hindu University, Varanasi, Uttar Pradesh, India.
Introduction:
Acromioclavicular joint (ACJ) injuries are prevalent among young, active individuals and account for a significant proportion of shoulder girdle and collision sports injuries. The Rockwood classification system categorizes these injuries from Type I to VI, guiding treatment from conservative management to surgical intervention. Despite various surgical techniques, including the Fiber-loop Endobutton method, failure rates, and complications remain a concern, particularly in cases of post-operative instability.
Case Report:
A 50-year-old male presented with persistent right shoulder pain and deformity following an initial Type-V ACJ injury from a road traffic accident. The patient had undergone surgical stabilization with a Fiber-loop Endobutton construct. However, 17th days post-surgery, he experienced a recurrence of pain and deformity, with radiographs revealing the failure of the initial repair. Subsequent imaging indicated a mal-positioned Endobutton and potential coracoid blowout, likely due to inadequate drill hole placement. Three weeks later, the patient underwent revision surgery using a double figure-of-8 autogenic loop reconstruction with FiberTape and hamstring tendon graft. The procedure involved removing the failed hardware, drilling new holes in the clavicle, and securing the ACJ with FiberTape and a hamstring graft. The graft was looped around the coracoid and clavicle in a figure-of-8 manner to replicate acromioclavicular ligament anatomy and ensure both horizontal and vertical stability. At 6 weeks, follow-up radiographs demonstrated near-anatomic alignment of the ACJ and coracoclavicular. The patient reported minimal pain and regained a near-full range of motion. By 6 months, while slight radiographic changes were noted, the patient remained asymptomatic with excellent functional outcomes and minimal limitations.
Conclusion:
This case highlights the challenges of managing post-operative instability in ACJ injuries. The successful use of a dual figure-of-8 graft technique provides a viable solution for revision surgery, offering satisfactory stability and functional recovery. Further research is needed to optimize salvage techniques for complex cases.