Related Experiment Video
Updated: May 14, 2025

Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography
Published on: May 27, 2008
Enhanced Imaging in Scanning Transmission X-Ray Microscopy Assisted by Ptychography
Shuhan Wu1,2,3, Zijian Xu1,2,3, Ruoru Li1,2,4
1Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China.
Abstract:
Scanning transmission X-ray microscopy (STXM) is a direct imaging technique with nanoscale resolution. But its resolution is limited by the spot size on the sample, i.e., by the manufacturing technique of the focusing element. As an emerging high-resolution X-ray imaging technique, ptychography utilizes highly redundant data from overlapping scans as well as phase retrieval algorithms to simultaneously reconstruct a high-resolution sample image and a probe function. In this study, we designed an accurate reconstruction strategy to obtain the probe spot with the vibration effects being eliminated, and developed an image enhancement technique for STXM by combining the reconstructed probe with the deconvolution algorithm. This approach significantly improves the resolution of STXM imaging and can break the limitation of the focal spot on STXM resolution when the scanning step size is near or below the spot size, while the data processing time is much shorter than that of ptychography. Both simulations and experiments show that this approach can be applied to STXM data at different energies and different scan steps using the same focal spot retrieved via ptychography.
More Related Videos
10:18Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
Published on: February 21, 2017
07:06Use of Micro X-ray Computed Tomography with Phosphotungstic Acid Preparation to Visualize Human Fibromuscular Tissue
Published on: September 5, 2019
Related Concept Videos
Overview of Microscopy Techniques
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Transmission Electron Microscopy
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging
Scanning Electron Microscopy
Fundamental Principles
Accelerated...