Related Experiment Video
Updated: Aug 5, 2026

Chronic Ovine Model of Right Ventricular Failure and Functional Tricuspid Regurgitation
Published on: March 17, 2023
Pulmonary Artery Banding in a Cat with Atrioventricular Canal Defect Type A with Concurrent Muscular Septal Defect
Olga Szaluś-Jordanow1, Krzysztof Zdeb2, Wojciech Mądry3
1Department of Small Animal Diseases with Clinic, Institute of Veterinary Medicine, Warsaw University of Life Sciences-SGGW, Nowoursynowska Str. 159c, 02-776 Warsaw, Poland.
Insights
Pulmonary artery banding (PAB) effectively managed an incomplete atrioventricular canal (AVC) defect in a cat, offering a palliative solution for this rare congenital heart condition. The procedure resulted in long-term stability and improved survival for the feline patient.
Area of Science:
- Veterinary Cardiology
- Congenital Heart Defects in Animals
Background:
- Describes the surgical management of pulmonary artery banding (PAB) for a cat with an incomplete atrioventricular canal (AVC) defect.
- Highlights PAB as a palliative treatment for a rare congenital heart condition in companion animals.
Background:
This case report describes the surgical management of pulmonary artery banding (PAB) in a cat diagnosed with an incomplete atrioventricular canal (AVC) defect and a concurrent muscular septal defect. It highlights the use of PAB as a palliative treatment to manage this rare congenital heart condition in companion animals.
Case Presentation:
A 9-month-old European long-haired male cat presented with clinical signs of heart failure. Pharmacological treatment with sildenafil and furosemide failed to stabilize the patient's condition. Echocardiographic assessment revealed an incomplete AVC type A and a muscular septal defect. Pulmonary artery banding was performed to reduce pulmonary blood flow and alleviate heart failure symptoms. Pre- and postoperative echocardiographic evaluations were conducted to monitor structural and functional changes in the heart. Post-surgical outcomes included a marked reduction in the size of the right atrium and ventricle and a stable pulmonary artery flow velocity of 3.8 m/s. The cat has remained in very good condition without the need for pharmacotherapy for 13 months post-surgery and is still alive at the time of reporting.
Conclusions:
PAB proved effective as a palliative intervention for managing an incomplete AVC in this feline patient. The successful outcome suggests that PAB may offer significant long-term benefits and improved survival in selected cases of incomplete AVCs in cats.
More Related Videos
Related Concept Videos
Chambers of the Heart
Deoxygenated blood from the body is received in the right...
Mitral Stenosis I: Introduction
Aortic Regurgitation I: Introduction

