Related Experiment Video
Updated: May 14, 2025

Addressing Practical Issues in Atomic Force Microscopy-Based Micro-Indentation on Human Articular Cartilage Explants
Published on: October 28, 2022
The Impact of Probe Angle and Swivel Length on Contact Point Identification in Coordinate Measuring Machine
Tomasz Mazur1, Tomasz Szymanski2, Waldemar Samociuk3
1Faculty of Mechanical Engineering, Casimir Pulaski Radom University, ul. Stasieckiego 54, 26-600 Radom, Poland.
Investigating coordinate measurement accuracy for Industry 4.0, this study found probe head angle significantly impacts contact point identification. Angles up to 15° caused negligible errors, but 90° introduced up to 10 μm errors, affecting calculations.
Area of Science:
- Metrology and Manufacturing Engineering
- Coordinate Measurement Technology
- Industry 4.0 Applications
Background:
- Accurate contact point identification is vital for precision in coordinate measurement systems.
- Industry 4.0 emphasizes data integrity and process control, making measurement accuracy paramount.
- Understanding probe head dynamics is essential for reliable metrology.
Purpose of the Study:
- To investigate the impact of probe declination angle and swivel length on contact point identification accuracy.
- To quantify errors introduced by varying probe head angles during coordinate measurements.
- To assess the implications of these errors on subsequent calculations and measurement results.
Main Methods:
- Experimental analysis of contact point deviations from (0,0,0) coordinates.
- Systematic variation of probe head rotational angles (stylus declination).
- Comparison of measurement errors against Coordinate Measuring Machine (CMM) accuracy.
Main Results:
- Vertical stylus positioning (0°) may introduce minor errors.
- Angles up to 15° resulted in negligible additional errors.
- Angles up to 90° introduced significant errors, reaching up to 10 μm.
Conclusions:
- Probe head angle critically influences contact point identification accuracy.
- High declination angles (approaching 90°) lead to substantial measurement errors.
- These errors can affect best-fit element calculations and overall measurement reliability in advanced manufacturing.
Related Concept Videos
Adjusting a Traverse
Atomic Force Microscopy
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
Angle of Twist: Problem Solving
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
Two-Dimensional Force System: Problem Solving
The first step to solving a two-dimensional force system problem is to draw a free-body diagram of the object under consideration. This diagram helps identify all the external forces acting on the object, including their...
Overview of Microscopy Techniques