Related Experiment Video
Updated: May 20, 2025

Stereotactic Radiosurgery for Gynecologic Cancer
Published on: April 17, 2012
Impact of the Common Terminology Criteria for Adverse Events (CTCAE) evolution on toxicity scoring in gynaecological
Sofia Spampinato1, Kari Tanderup2, Amelia Barcellini3
1Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, The Netherlands.
Purpose:
The Common Terminology Criteria for Adverse Events (CTCAE) is the established toxicity scoring system that assigns severity grades (G1 = mild to G5 = death) to Adverse Events (AEs). Compared to CTCAE v3.0 (2006), updated versions introduced changes in severity grade definitions. This study evaluated changes between v3.0 and v5.0 (2017) for AEs in gynaecological radiotherapy.
Material And Methods:
After selecting AEs relevant for gynaecological radiotherapy in v3.0, changes in severity grades were identified using CTCAE v3.0-to-v5.0 mapping tables. Six radiation oncologists (ROs) evaluated severity grade definitions for changes in: clinical interpretation, subjective (patient-reported symptoms) and objective (details on medication/intervention) information, and expected severe (≥G3) events. Agreement was based on at least five (≥5)ROs.
Results:
Gastrointestinal, urinary, reproductive, general and injury/musculoskeletal AEs were selected (n = 118). G4 definitions in v5.0 were removed in 22 % of AEs. ≥5ROs agreed on changes affecting clinical interpretation especially for G2 (31 %) and G3 (30 %). For subjective information, 18 % of G2 and 15 % of G3 were judged relying more on patient-reported symptoms. Less objective information was found in 51 % of G3 definitions. Variability in agreement was observed especially for subjective information in G3 and expected ≥G3 events.
Conclusion:
This analysis revealed that severity grade definitions in v3.0 and v5.0 for AEs in gynaecological radiotherapy present changes with potential impact on scoring in clinical studies. Notably, 22 % of AEs in v5.0 no longer have G4 defined, and G3 definitions often include fewer details on medication/intervention. Variability in ROs' interpretations is frequently observed, highlighting the need for education to standardise toxicity scoring.
More Related Videos
05:39Author Spotlight: Radiotherapy and Clonogenic Assays for Advancing Cancer Research and Personalized Medicine
Published on: April 5, 2024
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT