Management of power in single rotor wind turbine systems using fuzzy controller based on fractional order error
Habib Benbouhenni1, Adil Yahdou2, Z M S Elbarbary3,4
1LAAS Laboratory, Department of Electrical Engineering, National Polytechnic School of Oran- Maurice Audin, BP 1523 Oran El M'naouer, Oran, Algeria. habib.benbouhenni@enp-oran.dz.
Abstract:
Fuzzy Logic (FL) is a well-established artificial intelligence technique, particularly valuable in control applications where system modeling is either highly complex or impractical. However, its dependence on heuristic knowledge and rule-based decision-making can limit its precision and adaptability in dynamic environments. To address these challenges, this study introduces an enhanced FL-based control strategy that incorporates fractional-order error (FOE) to improve control performance in a single-rotor wind turbine system. The proposed FOE-based FL approach is applied to overcome the problems of the direct power control (DPC) of doubly-fed induction generators (DFIGs), leveraging fractional calculus to enhance system response, robustness, and efficiency. Extensive MATLAB-based simulations validate the effectiveness of the DPC-FOE-FL method with pulse width modulation compared to conventional DPC-FL control. The comparative analysis reveals that the proposed method significantly reduces energy fluctuations and harmonic distortion in the stator current, achieving a 40.85% reduction in the first test and a 34.21% reduction in the second test relative to traditional DPC-FL control. Additionally, the DPC-FOE-FL approach effectively suppresses reactive power overshoot, demonstrating reductions of 96.28%, 96.27%, and 54.56% across multiple test scenarios. Active power ripples are also minimized by 64.37%, 62.59%, and 62.96%, highlighting the method's superior dynamic performance. These findings confirm that integrating FOE into FL-based controllers significantly enhances power control stability and efficiency in wind energy systems. The DPC-FOE-FL technique offers a promising solution for optimizing renewable energy applications, particularly in fluctuating wind conditions, by ensuring greater precision, adaptability, and robustness in power regulation.
Related Concept Videos
Turbine-Governor Control
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Wind Turbine Machine Models
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
Load-frequency control
Control of Power Flow
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...