Related Experiment Video
Updated: May 13, 2025

Movement Retraining using Real-time Feedback of Performance
Published on: January 17, 2013
Comparison of markerless and marker-based motion analysis accounting for differences in local reference frame
Camilla Antognini1, Ariana Ortigas-Vásquez2, Christopher Knowlton3
1Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA; Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, IL, USA.
Abstract:
Markerless motion analysis offers a promising alternative to traditional marker-based motion capture. Differences between the kinematic signals obtained with these systems have been reported, but the hypothesis that these differences stem from reference frame alignment inconsistencies has not been systematically assessed. This study aims to apply a reference frame alignment method (REFRAME) to markerless captured knee kinematic signals to determine if inconsistencies with marker-based results are related to differences in local frame orientation. Ten healthy subjects (5/5 M/F, age 26.8 ± 5.6 years, 21.5 ± 1.8 kg/m2) were recruited to perform five walking trials each. Data was simultaneously recorded using eight video cameras (Miqus, Qualisys) for the markerless capture system (Theia3D), and twenty-four cameras (Oqus and Arqus, Qualisys) for the marker-based system (Qualisys). Both sets of processed data were exported for kinematic analysis in Visual3D (C-Motion). Implementing the REFRAME approach optimized the markerless kinematic signals towards the marker-based system, resulting in an average rotation of the tibia coordinate system of 13.8° ± 3.1° and 4.9° ± 3.6° around the y- and z-axes, respectively, and 5.3° ± 2.8°, 5.8° ± 2.4°, and 7.9° ± 4.9° for the femur coordinate system around the x-, y-, and z-axes, respectively. Post-REFRAME results showed improved agreement between markerless and marker-based data in all three planes. The root-mean-square error decreased from 3.9° ± 1.5° to 1.7° ± 0.2° (sagittal plane), from 6.1° ± 1.3° to 1.7° ± 0.3° (frontal plane), and from 10.2° ± 2.8° to 2.5° ± 0.5° (transverse plane). These findings indicate that most of the differences between markerless and marker-based data are likely due to inconsistencies in local frame orientations, suggesting that markerless kinematic signals represent fundamentally similar underlying motion waveforms.
Related Concept Videos
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...
Relative Motion Analysis - Acceleration
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
Inertial Frames of Reference

