Related Experiment Video
Updated: May 13, 2025

An Efficient Single—Person Technique for Milk Sampling from Laboratory Mice
Published on: March 28, 2025
Examining the Effect of Bottle Angle on Milk Drip Rate Using the Dr. Brown's® Zero-Resistance® Specialty Feeding
Jessica L Chee-Williams1,2, Lauren L Madhoun3, Kristen DeLuca4
1Program of Speech and Hearing Science, College of Health Solutions, Arizona State University, Tempe, AZ, USA.
Abstract:
ObjectiveExamine the drip rate from the Dr. Brown's® Zero-Resistance® Specialty Feeding System without compression across 8 nipple levels and 3 angles.DesignCross-sectional.SettingLaboratory.InterventionsThe drip rate of the Dr. Brown's® Zero-Resistance® Specialty Feeding System was assessed with the bottle positioned at 0°, 30°, and 45° angles across 8 bottle nipple levels: Ultra-Preemie™, Preemie Flow™, Level T, Level 1, Level 2, Level 3, Level 4, and Y-Cut.Main Outcome Measure(s)Milk volume in millimeters extracted per minute (mL/min) for each bottle nipple level and angle configuration. A one-way analysis of variance was conducted to compare the milk drip rate across 3 angles for each bottle nipple level.ResultsThe mean drip rate was 0.0 mL/min across all nipple levels when the bottle was positioned at a 0° angle. No milk drip was observed at any angle for the Y-Cut nipple. Milk drip was observed when the bottle angle increased to 30° and 45° for nipple levels Ultra-Preemie™ to Level 4 ranging from 1.3 mL/min up to 19.4 mL/min.ConclusionsMilk freely drips from the Dr. Brown's® Zero-Resistance® Specialty Feeding System when positioned at 30° and 45° angles for nipples Ultra-Preemie™ through Level 4, putting infants at risk for aspiration. Clinicians should recommend caregivers position the Specialty Feeding System at a 0° angle when infants pause to breathe.
More Related Videos
07:38Milk Collection in the Rat Using Capillary Tubes and Estimation of Milk Fat Content by Creamatocrit
Published on: December 16, 2015
08:29An Open Source Technology Platform to Manufacture Hydrogel-Based 3D Culture Models in an Automated and Standardized Fashion
Published on: March 31, 2022
Related Concept Videos
Viscosity
The SI unit of viscosity is...
Pipe Flowrate Measurement: Problem Solving
Turbulent Flow: Problem Solving
Temperature is a key factor in CO2 solubility. In this case, the CO2 gas and the liquid are cooled to 20°C. Lower temperatures...
Rise of Liquid in a Capillary Tube
Accelerating Fluids
The motion of the liquid within this infinitesimal cylinder is considered to obtain the pressure difference. Three vertical forces act on this liquid:
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...