The Correlation Between Fetal Wellbeing and Umbilical Doppler Parameters in Pregnant Women with Gestational
Hualan Lin1, Meifang Shen1, Dongbei Li1
1Obstetrical Department, Meizhou people's Hospital, Meizhou City, Guangdong Province, 514000, People's Republic of China.
Objective:
To investigate the role of umbilical cord blood flow parameters in evaluating intrauterine fetal hypoxia and fetal growth restriction in pregnant women with gestational hypertension.
Methods:
One hundred and nine patients with gestational hypertension admitted from January 2020 to December 2023 were enrolled in this study. The peak systolic velocity/end diastolic velocity (S/D), pulse index (PI) and resistance index (RI) of cord blood were measured by ultrasound. According to the S/D, 109 cases were divided into 62 cases in the control group (S/D < 3) and 47 cases in the observation group (S/D ≥ 3), and the prognosis of pregnant women and fetuses in the two groups were compared. The ROC curves were used to analyze the effects of different parameters of umbilical blood flow on intrauterine fetal hypoxia and fetal growth restriction in pregnant women with gestational hypertension.
Results:
The incidence of intrauterine fetal hypoxia, fetal growth restriction, cesarean section, and unresponsive type of non-irritation test was decreased in the control group compared with the observation group (P < 0.05). However, there was no statistical difference in the incidence of neonatal asphyxia between the two groups (P > 0.05). ROC curve analysis showed that cord blood flow RI of pregnant women with gestational hypertension had the highest sensitivity and AUC in predicting intrauterine fetal hypoxia and growth restriction, and PI had the highest specificity in predicting intrauterine fetal growth restriction. The specificity of S/D, PI and RI in predicting intrauterine hypoxia was consistent (all 80%).
Conclusion:
The different parameters of umbilical blood flow in hypertensive pregnant women during pregnancy provide a good assessment of intrauterine fetal condition and can be used as clinical indicators to predict poor prognosis of intrauterine fetal hypoxia and fetal growth restriction.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.