Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
Advancements in Noninvasive Volatile Organic Compound Detection: Integrating Stirling Cooling Preconcentration with
Qiongdan Xu1, Xiaoyu Hu2, Lei Zhong2
1Key Laboratory of Beijing on Regional Air Pollution Control, College of Environmental Science and Engineering, Beijing University of Technology, Beijing 100124, China.
Abstract:
The study of volatile organic compounds (VOCs) in exhaled breath presents significant potential for noninvasive disease diagnosis and human exposure monitoring. While thermal desorption (TD) tubes are the most commonly used preconcentration technique for analyzing VOCs in breath, they still face practical challenges, mainly selective adsorption and interference from water vapor in breath samples. This study is the first to develop a method combining Stirling cooling preconcentration technology with gas chromatography-flame ionization detector/mass spectrometry (GC-FID/MS) and a SUMMA canister, enabling simultaneous detection of 116 VOCs. The method requires no refrigerants and effectively addresses the selective adsorption and water vapor interference issues found with TD tubes. Furthermore, nitrogen pressurization is used to dilute the original gas, and calibration curves encompassing various linear ranges are developed to quantify the targeted VOCs across different concentration levels. Finally, we analyzed exhaled breath samples from eight healthy subjects and validated the method. The results showed that the coefficients of determination (R 2) for the linear equations of all target compounds exceeded 0.998, with limits of detection and quantification (LOQ) ranging from 0.01 to 0.09 ppbv and 0.03 to 0.35 ppbv, respectively, and precision within 20%. Accuracy, except for a few substances, was generally between 70% and 130%. This study offers robust technical support for the accurate quantification of VOCs at various concentration levels in exhaled breath.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...