Related Experiment Video
Updated: Jun 15, 2025

Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach
Published on: January 24, 2018
Image-free robotic-assisted total knee arthroplasty is associated with joint line distalization and improves
Keisuke Maeda1,2, Tomoharu Mochizuki1, Shigeru Takagi1
1Division of Orthopedic Surgery Niigata University Medical and Dental Hospital Niigata Japan.
Purpose:
Total knee arthroplasty (TKA) has demonstrated long-term durability, with a significant reduction in revisions due to polyethylene wear and component loosening. However, mid-flexion instability (MFI) is a key factor in early TKA revisions, affecting patient satisfaction and implant longevity. Recent advancements in robotic-assisted TKA (raTKA) provide precise joint line (JL) restoration and component positioning, potentially reducing MFI. This prospective study evaluated the impact of image-free raTKA on MFI and JL restoration.
Methods:
This prospective cohort study included 59 knees undergoing primary TKA using the image-free robotic systems NAVIO® and CORI® and the JOURNEY II® Bi-Cruciate Stabilized knee system. Intraoperative component gap (CG) measurements at 0°, 30°, 60° and 105° of flexion were taken, and JL changes were assessed pre- and post-operatively using computed tomography (CT)-based three-dimensional (3D) models with the 3D-3D matching technique. The distal femoral JL was quantified.
Results:
Both the medial and lateral CG at 30° and 60° were significantly smaller compared to those at 0° and 105°. Post-operative JL showed distalization of 1.5 mm at the medial femur and 2.0 mm at the lateral femur compared to preoperative JL.
Conclusions:
This study is the first to assess JL restoration in raTKA using CT-based bone landmarks, offering precise insights. Image-free raTKA facilitates precise JL restoration, optimizing knee kinematics and enhancing stability. These findings suggest that this technique contributes to improved post-operative joint function and greater patient satisfaction.
Level Of Evidence:
Level II, prospective cohort study.