Related Experiment Videos
Determination of the stability of tetracycline suspensions by high performance liquid chromatography
Pharmaceutisch Weekblad. Scientific Edition
|June 21, 1985
Abstract:
High performance liquid chromatography was used to examine the stability of tetracycline suspensions, prepared according to the Formulary of the Dutch Pharmacists and the National Formulary v (Belgium). The influence of the nature of the buffer salt, of the pH, and of the temperature and time of storage are discussed. At slightly acid pH (4 to 5.5) and at room temperature suspensions are stable for at least three months.