Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Data Validation01:15

Data Validation

127
Method validation is a crucial process in analytical chemistry designed to confirm that a given method consistently produces reliable and high-quality results. This process is essential when a method is applied to different sample matrices or when procedural modifications are made, ensuring that the results meet acceptable standards across various applications.
Key parameters for method validation include:
127
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving01:29

Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving

29
Mechanistic models play a crucial role in algorithms for numerical problem-solving, particularly in nonlinear mixed effects modeling (NMEM). These models aim to minimize specific objective functions by evaluating various parameter estimates, leading to the development of systematic algorithms. In some cases, linearization techniques approximate the model using linear equations.
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
29
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation01:24

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation

233
This lesson introduces two critical methods in pharmacokinetics, the Wagner-Nelson and Loo-Riegelman methods, used for estimating the absorption rate constant (ka) for drugs administered via non-intravenous routes. The Wagner-Nelson method relates ka to the plasma concentration derived from the slope of a semilog percent unabsorbed time plot. However, it is limited to drugs with one-compartment kinetics and can be impacted by factors like gastrointestinal motility or enzymatic degradation.
On...
233
Maxwell-Boltzmann Distribution: Problem Solving01:20

Maxwell-Boltzmann Distribution: Problem Solving

1.3K
Individual molecules in a gas move in random directions, but a gas containing numerous molecules has a predictable distribution of molecular speeds, which is known as the Maxwell-Boltzmann distribution, f(v).
This distribution function f(v) is defined by saying that the expected number N (v1,v2) of particles with speeds between v1 and v2 is given by
1.3K
Bernoulli's Equation: Problem Solving01:16

Bernoulli's Equation: Problem Solving

513
A Venturi meter is essential for measuring fluid flow rates in pipelines. It utilizes the relationship between fluid velocity and pressure described by Bernoulli's equation. When installed in a sewage system, the Venturi meter accurately determines the wastewater flow rate by measuring pressure differences.
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity...
513
Region of Convergence of Laplace Tarnsform01:20

Region of Convergence of Laplace Tarnsform

421
The Region of Convergence (ROC) is a fundamental concept in signal processing and system analysis, particularly associated with the Laplace transform. The ROC represents an area in the complex plane where the Laplace transform of a given signal converges, determining the transform's applicability and utility.
Consider a decaying exponential signal that begins at a specific time. When deriving its Laplace transform, the time-domain variable is replaced with a complex variable. This...
421

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Establishing typical diagnostic reference levels in a Peruvian nuclear medicine centre: a retrospective study.

Radiation protection dosimetry·2026
Same author

Occupational dose attenuation and dosimetric performance of autonomous radiation protection systems in fluoroscopy: a scoping review with implications for the role of conventional lead aprons.

Journal of radiological protection : official journal of the Society for Radiological Protection·2026
Same author

Development and Execution of a Pediatric Hospice and Palliative Medicine Fellowship in Latin America.

Journal of graduate medical education·2026
Same author

Network-Based Asynchronous Research Training in Breast Imaging: A Multinational Pre-Post Evaluation for Cancer Education.

Journal of cancer education : the official journal of the American Association for Cancer Education·2026
Same author

Mechanical Performance of Plywood TIE Joints Under Tension and Shear in the WikiHouse Skylark Modular System.

Materials (Basel, Switzerland)·2025
Same author

Density-Based Topology-Optimized 3D-Printed Fixtures for Cyclic Mechanical Testing of Lattice Structures.

Polymers·2025

Related Experiment Video

Updated: May 13, 2025

An R-Based Landscape Validation of a Competing Risk Model
05:37

An R-Based Landscape Validation of a Competing Risk Model

Published on: September 16, 2022

2.0K

Development and Validation of Monte Carlo Methods for Converay: A Proof-of-Concept Study.

Rodolfo Figueroa1,2, Francisco Malano1,2, Alejandro Cuadra3

  • 1Centro de Excelencia de Física e Ingeniería en Salud (CFIS), Universidad de La Frontera, Temuco 4811230, Chile.

Cancers
|April 14, 2025
PubMed
Summary

The CONVERAY teletherapy system uses a convergent X-ray beam for highly conformal radiotherapy. Simulations show it can achieve high dose concentrations in tumors, improving treatment precision.

Keywords:
CONVERAY systemMonte Carlo simulationconvergent beam radiotherapy

More Related Videos

Surrogate Model Development for Digital Experiments in Welding
09:17

Surrogate Model Development for Digital Experiments in Welding

Published on: March 28, 2025

584
Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
13:07

Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression

Published on: January 15, 2022

3.8K

Related Experiment Videos

Last Updated: May 13, 2025

An R-Based Landscape Validation of a Competing Risk Model
05:37

An R-Based Landscape Validation of a Competing Risk Model

Published on: September 16, 2022

2.0K
Surrogate Model Development for Digital Experiments in Welding
09:17

Surrogate Model Development for Digital Experiments in Welding

Published on: March 28, 2025

584
Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
13:07

Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression

Published on: January 15, 2022

3.8K

Area of Science:

  • Medical Physics
  • Radiation Oncology
  • Medical Imaging

Background:

  • Advancements in radiotherapy aim to improve tumor control and reduce normal tissue complications.
  • High dose conformity on complex targets is a key goal in modern radiation therapy.
  • The CONVERAY project introduces a novel teletherapy system with a convergent X-ray beam.

Purpose of the Study:

  • To introduce and evaluate the CONVERAY teletherapy system.
  • To assess the dosimetry performance and dose distribution capabilities of the CONVERAY device.
  • To validate the concept of a convergent X-ray beam for radiotherapy.

Main Methods:

  • Developed customized Monte Carlo subroutines for simulating particle fluence and dosimetry.
  • Characterized radiation fluence and interaction processes for the CONVERAY device.
  • Integrated CONVERAY simulations with a conventional clinical linear accelerator head.

Main Results:

  • Monte Carlo simulations successfully characterized convergent photon beam production.
  • The CONVERAY device demonstrated capability for high dose concentrations at the focal spot.
  • Simulations showed promising spatial dose concentration within tumor volumes for intracranial and pulmonary irradiations.

Conclusions:

  • The Monte Carlo study validated the CONVERAY prototype's ability to generate convergent X-ray beams.
  • Simulation results indicate potential for exceptionally high dose concentrations in complex treatment volumes.
  • The CONVERAY system shows promising dosimetry performance for advanced radiotherapy applications.