Related Experiment Video
Updated: May 22, 2025

The 4-vessel Sampling Approach to Integrative Studies of Human Placental Physiology In Vivo
Published on: August 2, 2017
Placental size and umbilical vein volume blood flow
Kari Flo1, Carl Petter Skaar Kulseng1,2, Helene Fjeldvik Peterson1,3
1Division of Obstetrics and Gynecology, Akershus University Hospital, Lørenskog, Norway.
Introduction:
The fetus receives oxygen and nutrition from the placenta through the umbilical vein. There is a large variation in placental size and placental size relative to fetal size (placental-fetal ratio). We studied whether placental size or placental-fetal ratio is related to blood flow in the umbilical vein.
Material And Methods:
We performed a prospective study at Akershus University Hospital in Norway and a total of 73 women were examined in gestational weeks 27 and 37. Fifty-six women were examined at both time points. B-mode ultrasound and Doppler ultrasonography were used to measure the umbilical vein volume blood flow per minute. Magnetic resonance imaging was used to measure placental and fetal volume. Pearson's and Spearman's correlation coefficients were applied for estimations of associations.
Results:
In gestational week 27, the umbilical vein volume blood flow was positively correlated with fetal size (Pearson's correlation coefficient r = 0.372, p = 0.003, and Spearman's correlation coefficient r = 0.384, p = 0.002), but not with placental size (Pearson's r = 0.130, p = 0.317, and Spearman's r = - 0.53, p = 0.687) or placental-fetal ratio (Pearson's r = - 0.61, p = 0.641, and Spearman's r = - 0.218, p = 0.092). In gestational week 37, we found positive correlations of the umbilical vein volume blood flow with fetal size (Pearson's r = 0.428, p = <0.001, and Spearman's r = 0.391, p <0.001), placental size (Pearson's r = 0.400, p = 0.001, and Spearman's r = 0.643, p <0.001), and with placental-fetal ratio (Pearson's r = 0.224, p = 0.066, and Spearman's r = 0.266, p = 0.028).
Conclusions:
A large placenta and a high placental-fetal ratio are associated with increased umbilical vein blood flow.
Related Concept Videos
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Development of Blood Vessels
The initial formation of this system is facilitated by the small amount of yolk present in the ovum and yolk sac. Blood vessels originate from...
Veins of the Abdomen and Pelvis
The inferior vena cava is fed by numerous smaller veins. The lumbar veins, for instance, drain the posterior abdominal wall, emptying both directly into the inferior vena cava and into the...
Blood Flow
Veins as Blood Reservoirs
Overview of Systemic Veins
The coronary sinus, the heart's principal vein, resides in the coronary sulcus on the heart's posterior aspect. This broad venous channel receives nearly all venous blood from the myocardium, the heart muscle. It is fed by three primary veins: the great cardiac vein, the...

