Related Experiment Video
Updated: May 13, 2025

Ex Vivo Porcine Experimental Model for Studying and Teaching Lung Mechanics
Published on: April 19, 2024
The impact of suction duration on lung collapse during one-lung ventilation
Lihua Hang1, Jiajun Ju1, Yulin Li1
1Department of Anesthesiology, Kunshan Hospital Affiliated to Jiangsu University, Kunshan, China.
Objective:
To investigate the effect of suction duration on lung collapse when using a bronchial blocker (BB) during single-port video-assisted thoracoscopic surgery (VATS) with one-lung ventilation (OLV).
Methods:
This study included 112 patients (39 males, 73 females; aged 18-75 years) with ASA physical status I or II undergoing single-port VATS under general anesthesia. Patients were randomized into four groups: control (0 s), 30 s, 60 s, and 90 s suction groups (-30 cmH₂O; n = 28/group). Lung collapse scores (LCS) were recorded immediately after thoracoscope entry (T0) and at 10 min (T10). The expression of nitric oxide synthase 3 (NOS-3) mRNA in lung tissue was analyzed using PCR. Lung injury pathology scores, the wet-to-dry weight ratio (W/D) of lung tissue, intraoperative hypoxemia, perioperative pulmonary complications, and use of disconnection techniques for inadequate collapse were documented.
Results:
At T0, LCS in the 30 s, 60 s, and 90 s groups were significantly higher than in the control group (P < 0.05), with no differences among the suction groups. At T10, LCS in the 60 s and 90 s groups were significantly higher than in the control group (P < 0.05), while no significant differences were observed between the 30 s and control groups. NOS-3 mRNA expression, lung injury pathology scores, and W/D ratios were comparable across groups. No severe hypoxemia or pulmonary complications occurred. Rescue techniques were required in four control group patients and one patient in the 30 s group but not in the 60 s and 90 s groups (P < 0.05).
Conclusion:
Suction at -30 cmH2O for 60 s immediately after pleural incision during one-lung ventilation with a bronchial blocker in single-port VATS significantly improves lung collapse quality without causing lung injury, making it a clinically recommended practice.
More Related Videos
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
09:31Normothermic Negative Pressure Ventilation Ex Situ Lung Perfusion: Evaluation of Lung Function and Metabolism
Published on: February 14, 2022
Related Concept Videos
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Cycle: Exhalation
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Suctioning the Nasopharyngeal Airway
Equipment Required