Related Experiment Video
Updated: May 14, 2025

On-chip Isotachophoresis for Separation of Ions and Purification of Nucleic Acids
Published on: March 2, 2012
Development of universal isotachophoresis - capillary zone electrophoresis method for trace determination of bromide
Marián Masár1, Jasna Hradski1, Roman Szucs1
1Department of Analytical Chemistry, Faculty of Natural Sciences, Comenius University Bratislava, Ilkovičova 6, SK-84215, Bratislava, Slovakia.
Abstract:
Trace determination of bromide in water samples and high-purity chemicals was accomplished by capillary zone electrophoresis (CZE) with online isotachophoresis (ITP) sample pretreatment and photometric detection at 200 nm. The adverse effect of bromide on human health necessitates its monitoring in drinking water. Bromide is also a precursor of bromate, a carcinogenic by-product of water disinfection that can be formed in drinking water during ozonation (oxidation of bromide to bromate). ITP-CZE separations were performed at acidic pH (2.7) as this facilitates high selectivity of the separation system. Addition of the zwitterionic surfactant N-dodecyl-N,N-dimethyl-3-ammonio-1-propanesulfonate to the leading electrolyte enhanced the separation of bromide from anionic macrocomponents in drinking water. The first separation step, ITP, served as a very efficient sample clean-up. Linear response was observed in the presence and absence of matrix in the concentration range 1-50 μg/L. ITP-CZE separations were characterized by very good repeatability of migration times (up to 0.4 % RSD) as well as peak areas (up to 3.7 % RSD) of bromide. The achieved limit of detection for bromide was 0.3 μg/L in the presence of matrix. To assess the practical applicability of the developed test procedure, samples of mineral and drinking water, as well as highly pure chloride salts, were analyzed. Recoveries of bromide in the analyzed samples were in the range of 98-103 %. The developed ITP-CZE method can be used for highly selective determination of trace concentrations of bromide present in ionogenic samples.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
08:06Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone
Published on: February 23, 2017
Related Concept Videos
Ion-Exchange Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is:
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...