A Metadata Extraction Approach for Clinical Case Reports to Enable Advanced Understanding of Biomedical Concepts
Published on: September 20, 2018
Large-Scale Integration of DICOM Metadata into HL7-FHIR for Medical Research
Alexa Iancu1,2, Johannes Bauer3, Matthias S May4
1Friedrich-Alexander-Universität Erlangen-Nürnberg, Medical Informatics, Erlangen, Germany.
Background:
The current gap between the availability of routine imaging data and its provisioning for medical research hinders the utilization of radiological information for secondary purposes. To address this, the German Medical Informatics Initiative (MII) has established frameworks for harmonizing and integrating clinical data across institutions, including the integration of imaging data into research repositories, which can be expanded to routine imaging data.
Objectives:
This project aims to address this gap by developing a large-scale data processing pipeline to extract, convert, and pseudonymize DICOM (Digital Imaging and Communications in Medicine) metadata into "ImagingStudy" Fast Healthcare Interoperability Resources (FHIR) and integrate them into research repositories for secondary use.
Methods:
The data processing pipeline was developed, implemented, and tested at the Data Integration Center of the University Hospital Erlangen. It leverages existing open-source solutions and integrates seamlessly into the hospital's research IT infrastructure. The pipeline automates the extraction, conversion, and pseudonymization processes, ensuring compliance with both local and MII data protection standards. A large-scale evaluation was conducted using the imaging studies acquired by two departments at University Hospital Erlangen within 1 year. Attributes such as modality, examined body region, laterality, and the number of series and instances were analyzed to assess the quality and availability of the metadata.
Results:
Once established, the pipeline processed a substantial dataset comprising over 150,000 DICOM studies within an operational period of 26 days. Data analysis revealed significant heterogeneity and incompleteness in certain attributes, particularly the DICOM tag "Body Part Examined." Despite these challenges, the pipeline successfully generated valid and standardized FHIR, providing a robust basis for future research.
Conclusion:
We demonstrated the setup and test of a large-scale end-to-end data processing pipeline that transforms DICOM imaging metadata directly from clinical routine into the Health Level 7-FHIR format, pseudonymizes the resources, and stores them in an FHIR server. We showcased that the derived FHIRs offer numerous research opportunities, for example, feasibility assessments within Bavarian and Germany-wide research infrastructures. Insights from this study highlight the need to extend the "ImagingStudy" FHIR with additional attributes and refine their use within the German MII.
Related Concept Videos
Issues And Trends In Healthcare Delivery System
Cost Containment
Payment for healthcare services has historically promoted adoption of costly and often unnecessary or inefficient...
Health Information Technology and Healthcare Information System
Health Information Technology, commonly called HIT, integrates advanced information systems and technology in healthcare settings. Its primary functions include:
Methods of Documentation VII: EMR
Integrated Healthcare System
Purpose of Health Records II
Purpose of Health Records I
Here's a breakdown of how health records serve these purposes: