Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Use of complementary electrocardiogram-gated cardiac computed tomography in the assessment of aortic valve
Valentina Mescola1,2, Virginia Álvarez Asiaín3,4, Javier De Diego Candela1
1Department of Cardiovascular Surgery, Navarra University Hospital, Pamplona, Spain.
Objectives:
In young patients with type I/II aortic regurgitation, the feasibility of aortic valve (AV) repair has been traditionally evaluated with echocardiography. We evaluate electrocardiogram (ECG)-gated cardiac computed tomography as a complement to transoesophageal echocardiography in the preoperative assessment of aortic repairability.
Methods:
Patients undergoing non-urgent AV repair with or without aortic root replacement from October 2016 to May 2023 who had both imaging tests for the evaluation of AV repairability were included. The measurements obtained with echocardiography and ECG-gated scan of geometric height, aortic annulus and commissural orientation were compared using the intraclass correlation coefficient for inter-rater reliability.
Results:
All 24 patients were males, with a median age of 47.5 years (41.9-59.3). Of these, 87.5% presented severe aortic regurgitation; 62.5% had associated aortopathy. 58.3% were in New York Heart Association class I and the remnant 41.7% in class II. The AV was bicuspid in 62.5% of the patients. The intraclass correlation coefficient indicated excellent reliability of ECG-gated scan for commissural orientation (ICC = 0.98, 95% CI: 0.96-0.99) and conjoined cusp geometric height (ICC = 0.91, 95% CI: 0.74-0.97) in bicuspid AVs, while in tricuspid valves it showed good reliability for left cusp geometric height (ICC = 0.76, 95% CI: 0.19-0.93) and annular diameter (ICC = 0.8, 95% CI: 0.33-0.95).
Conclusions:
ECG-gated cardiac scan complements echocardiography in aortic repair, showing excellent agreement for morphologic evaluation and commissural orientation. It is particularly reliable for geometric height in bicuspid valves and annular diameter and left cusp geometric height in tricuspid valves.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Aortic Regurgitation I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Acute Coronary Syndrome III: Diagnostic Studies