Optimal allocation of hybrid PVDG and DSVC devices into distribution grids using a modified NRBO algorithm
Nasreddine Belbachir1, Mohamed Zellagui2, Haitham A Mahmoud3
1Department of Electrical Engineering, University of Mostaganem, 27000, Mostaganem, Algeria. nasreddine.belbachir.etu@univ-mosta.dz.
Abstract:
The never-ending issue of inadequate energy availability is constantly on the outermost layer. Consequently, an ongoing effort has been made to improve electric power plants and power system configurations. Photovoltaic Distributed Generators (PVDG) and compensators such as Distributed Static Var Compensator (DSVC) are the center of these recent advances. Due to its high complexity, these devices' optimum locating and dimensions are a relatively new issue in the Electrical Distribution Grid (EDG). A modified version of Newton Raphson Based Optimizer (mNRBO) has been carried out to optimally allocate the PVDG and DSVC devices in tested IEEE 33 and 69 bus EDG. The mNRBO algorithm integrates four parameters to enhance NRBO's performance by addressing its limitations in balancing exploration and exploitation. The article suggested novel Multi-Objective Functions (MOF), which have been considered to optimize concurrently the overall amount of active power loss (APL), voltage deviation (VD), relays operation time (TRELAY), as well as improve the coordination time interval (CTI) between primaries and backup relays set up in EDG. The proposed mNRBO algorithm surpasses its basic NRBO version, as long as another alternative algorithm, while providing very good results, such as minimizing the APL from 210.98 kW until 26.482 kW and 224.948 kW until 18.763 kW for the IEEE 33 and 69 bus respectively. Which proves the capability of the mNRBO algorithm of solving such power system challenges.
Related Concept Videos
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Maximum Power Flow and Line Loadability
Fast Decoupled and DC Powerflow
Primary Distribution
Power System Distribution
The transmission system is designed...