Related Experiment Video
Updated: May 13, 2025

Semiconductor Sequencing for Preimplantation Genetic Testing for Aneuploidy
Published on: August 25, 2019
Performance characteristics of three Brucella canis serological assays in the United States
Tessa E LeCuyer1, Rebecca Franklin-Guild2, Cassandra Guarino2
1Department of Pathology, Microbiology, and Immunology, School of Veterinary Medicine, University of California, Davis, Davis, CA, United States.
Abstract:
Brucella canis is a zoonotic pathogen of dogs that poses diagnostic challenges. While direct detection of B. canis by PCR or culture is ideal, serologic diagnosis is necessary for identification of carrier animals and can support a clinical diagnosis of brucellosis. Prior to 2022, B. canis seroscreening in the United States was primarily performed using a commercially available rapid slide agglutination test. However, the kit was discontinued by the manufacturer in early 2022, leaving a gap in the availability of commercial B. canis seroassays. The goal of this study was to compare the performance of three B. canis serologic tests that are currently available: VMRD Brucella ovis ELISA, Bionote Anigen Rapid C.Brucella Ab immunochromatographic lateral flow assay, and VMRD B. canis indirect fluorescent antibody (IFA) assay. A panel of 56 banked serum specimens originally submitted to the Cornell University Animal Health Diagnostic Center (the study reference laboratory) for B. canis seroscreening was distributed to 12 testing laboratories. Each sample was run on three assays developed at the reference lab: rapid slide agglutination test with 2-mercaptoethanol (2-ME RSAT), agar gel immunodiffusion test using cytoplasmic antigen (AGID II), and Canine Brucella Multiplex. Five testing labs ran the ELISA, six ran the lateral flow, and six ran the IFA. When evaluated as a screening assay, we compared the assays to the 2ME-RSAT. The ELISA had the highest sensitivity (96.8, 95%CI 83.8-99.9) but the lowest specificity (79.3, 95%CI 57.9-92.9). The sensitivity of the lateral flow was 90.6% (95%CI 75-98%) and the IFA was 87.5% (95%CI 71-96.5). Specificity for the lateral flow was 95.8% (95%CI 78.9-99.9) and IFA was 97.5% (95%CI 67.6-97.3). When compared to AGID II and Canine Brucella Multiplex, the test assays were all highly sensitive, but specificity was <90%. Interrater reliability was highest for IFA (Κ = 0.92) and lowest for the lateral flow (Κ = 0.82). Serial testing of positive samples with a more specific test, such as AGID II, will continue to be necessary when using any of the three assays tested in this study.
More Related Videos
06:11Author Spotlight: Exploring the Long-Term Health Impacts of Intracytoplasmic Sperm Injection on Offspring
Published on: May 17, 2024
12:32Chromosome Screening of Human Preimplantation Embryos by Using Spent Culture Medium: Sample Collection and Chromosomal Ploidy Analysis
Published on: September 7, 2021
Related Concept Videos
Three-Winding Transformers
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
Three-Phase Circuits
Self-Report Tests of Personality
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used...
Characteristics of Practical Op Amps
The ratio of differential gain to the common-mode gain is defined as the common-mode rejection ratio (CMRR). This ratio quantifies the ability of operational amplifiers (op-amps) to reject common-mode...
Power in a Three-Phase Circuit