Related Experiment Video
Updated: May 13, 2025

Quantifying Intermembrane Distances with Serial Image Dilations
Published on: September 28, 2018
Computed tomography ring artifact correction method with super-pixel segmentation and adaptive relative total
Na Li1, Yingchun Yin2, Junxiong Zhao3
1Department of Biomedical Engineering, Guangdong Medical University, Dongguan, China.
This study introduces a novel two-stage method to remove ring artifacts in computed tomography (CT) images, enhancing diagnostic accuracy. The technique effectively corrects both high and low-intensity artifacts, preserving image quality for photon counting CT (PCCT).
Area of Science:
- Medical Imaging
- Image Processing
- Photon Counting CT (PCCT)
Background:
- Ring artifacts are a persistent problem in computed tomography (CT) imaging, often caused by hardware inconsistencies.
- These artifacts degrade image quality, impacting diagnostic accuracy and clinical utility.
- Photon counting CT (PCCT) presents unique challenges for artifact removal due to its advanced technology.
Purpose of the Study:
- To develop and validate a comprehensive method for removing ring artifacts in CT images.
- To specifically address the challenges of artifact correction in photon counting CT (PCCT).
- To preserve essential image details and grayscale balance during artifact removal.
Main Methods:
- A two-stage artifact correction approach combining super-pixel segmentation and adaptive Relative Total Variation (RTV).
- Super-pixel segmentation is used for high-intensity artifact removal.
- Adaptive RTV, optimized by mesh adaptive direct search, addresses low-intensity artifacts.
Main Results:
- Significant reduction in both high and low-intensity ring artifacts was observed.
- The method successfully maintained the structural integrity and grayscale balance of CT images.
- The proposed technique demonstrated versatility and robustness across various imaging scenarios and equipment.
Conclusions:
- The developed method effectively removes ring artifacts in CT images, particularly for PCCT.
- This advancement improves image quality and supports new applications of PCCT in precision medicine.
- The study provides publicly available code for reproducibility.
More Related Videos
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
08:02Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
Published on: November 15, 2024