Detection of Mycobacterium ulcerans with IS2404 loop-mediated isothermal amplification and a fluorescent reporter
Jean Y H Lee1,2, Jessica L Porter1, Maria Globan3
1Department of Microbiology and Immunology, The University of Melbourne at the Doherty Institute for Infection and Immunity, Parkville, Victoria, Australia.
Abstract:
An exquisitely sensitive quantitative PCR (qPCR) assay targeting the high-copy number insertion sequence, IS2404, is the gold standard diagnostic test for Mycobacterium ulcerans, the agent of the neglected tropical skin disease Buruli ulcer. Here, we designed and tested an alternative M. ulcerans diagnostic test, a fluorescent probe-based, loop-mediated isothermal amplification (P-LAMP) assay that also targets IS2404. Benchmarked against IS2404 qPCR, P-LAMP was equally specific and nearly as sensitive (analytical sensitivity of four vs two M. ulcerans genome copies). Clinical and environmental specimen validation against IS2404 qPCR showed P-LAMP had 100% sensitivity and specificity. P-LAMP was twice as fast as qPCR with an average time-to-positive at the limit-of-detection of 19 minutes. P-LAMP targeting IS2404 is a versatile assay that addresses the performance issues of previously described IS2404 LAMP formats. This study tackles a key research priority for Buruli ulcer and represents another avenue for the development of rapid and accessible molecular diagnostics for this neglected tropical disease.IMPORTANCEBuruli ulcer is a neglected tropical disease caused by infection with Mycobacterium ulcerans. Correct diagnosis is essential before appropriate treatment for Buruli ulcer can be started. Development of a portable, easy-to-use diagnostic test for M. ulcerans has been identified by the World Health Organization as a research priority. Buruli ulcer most commonly occurs in remote, rural areas; therefore, an ideal test is one that can be used at (or near) the point of care (community health centres) without the need for specialized laboratories. Here, we describe a molecular test using loop-mediated isothermal amplification (LAMP) to detect DNA specific to M. ulcerans and show that this new test has equivalent performance to the gold standard M. ulcerans PCR test currently used worldwide. Our new test is rapid (30 minutes to run), simple to perform, and could be further developed into a robust, portable format to provide accessible and affordable M. ulcerans diagnostics anywhere.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...