Related Experiment Video
Updated: May 13, 2025

Additive Manufacturing-Enabled Low-Cost Particle Detector
Published on: March 24, 2023
Calibration and validation-based assessment of low-cost air quality sensors
Jierui Dong1, Nigel Goodman2, Andrew Carre3
1Sustainable Building Innovation Lab., School of Property, Construction and Project Management, RMIT University, Melbourne, VIC 3000, Australia; Healthy Environments And Lives (HEAL) National Research Network, Australia; Post Carbon Research Centre, RMIT University, Melbourne, VIC 3000, Australia.
Background:
Air pollution poses a significant threat to public health. Low-cost air quality sensors (LCSs) can provide a data foundation for air quality monitoring, particularly supplementing the regulatory monitoring network and identifying local air quality issues. However, the performance varies considerably, and questions remain regarding reliability and accuracy of LCS data.
Methods:
We evaluated the accuracy, stability and precision of six LCSs over a three-month period of collocation with reference instruments at two locations. A mathematical workflow including calibration and validation was developed for accuracy and stability, incorporating a combination of environmental factors (e.g., temperature, relative humidity), linear and nonlinear regression, followed by precision evaluation by Bland-Altman plots.
Results:
For particulate matter, data from LCSs was found to be reliable after simple linear regression (R2 > 0.9 for both calibration and validation). For gas sensors including nitrogen dioxide, carbon monoxide, and Ozone, nonlinear methods that met the validation requirements also performed well using simple linear regression models (R2 > 0.7 for both calibration and validation), whereas machine learning models, such as random forest, could not pass the validation, and require cautious application. In non-laboratory environments, incorporating environmental factors into the calibration function may lead to subsequent performance instability. Regarding precision between LCSs, unstable measurement biases among devices have been observed.
Conclusions:
Linear regression method is recommended as the preferred method for onsite calibration of LCSs, with caution advised when incorporating environmental factors due to increased uncertainty. Furthermore, when deploying LCSs, it is important to consider their varying responses to high or low pollutant concentrations.
More Related Videos
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
09:33Visualizing Field Data Collection Procedures of Exposure and Biomarker Assessments for the Household Air Pollution Intervention Network Trial in India
Published on: December 23, 2022
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Data Validation
Key parameters for method validation include: