Related Experiment Video For Breast neoplasms
Updated: May 11, 2025

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Comparison of contrast-enhanced cone-beam breast CT, MRI, and mammography for breast cancer characterization
Yue Ma1, Yafei Wang1, Yuwei Zhang1
1Department of Radiology, Tianjin Medical University Cancer Institute & Hospital, National Clinical Research Center for Cancer, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Key Laboratory of Cancer Prevention and Therapy, Tianjin, PR China.
Objectives:
To compare the consistency of contrast-enhanced cone-beam breast CT (CE-CBBCT), MRI and mammography regarding characterization of breast cancer.
Methods:
In this retrospective study, patients with breast cancer who underwent preoperative CE-CBBCT, MRI, and mammography between January 2017 and July 2022 were enrolled. Three experienced radiologists independently interpreted the characteristics of breast lesions on each imaging mode referring to BI-RADS, with a 4-week wash-out period. One of the three radiologists reviewed the CE-CBBCT images 4 weeks after the initial evaluation. Cross-modality consistency was calculated by Cohen's Kappa based on majority report. Inter-and intra-reader agreement were assessed using Fleiss and Cohen's Kappa, respectively. The association between imaging factors and consistency levels was analyzed using chi-square and Mann-Whitney U test.
Results:
A total of 214 malignant lesions identified in 207 patients were enrolled. CE-CBBCT showed almost perfect agreement with MRI on lesion type identification (Kappa = 0.865, 95% CI: 0.802-0.928), but fair agreement with mammography (Kappa = 0.287, 95% CI: 0.205-0.369). CE-CBBCT showed substantial agreement on characterization with MRI for both mass (Kappa = 0.752-0.824) and non-mass enhancement (NME) (Kappa = 0.702-0.729), and non-contrast-enhanced CBBCT (NCE-CBBCT) showed substantial agreement with mammography for calcification (Kappa = 0.717-0.777). Inter- (Kappa = 0.611-0.738) and intra-reader (Kappa = 0.757-0.887) agreement were substantial on CE-CBBCT interpretation. There was no statistically significant difference in imaging factors between different consistency levels (all p > 0.05).
Conclusions:
CE-CBBCT showed high consistency on mass and NME characterization with MRI, and on calcification with mammography, indicating that CE-CBBCT could combine morphology, hemodynamic and calcification features, and the corresponding descriptors have the feasibility to describe CE-CBBCT characteristics of breast cancer.
Key Points:
Question Contrast-enhanced cone-beam breast CT (CE-CBBCT) is widely used in the diagnosis and assessment of breast cancer, but there is no standardized lexicon for image interpretation. Findings CE-CBBCT showed high consistency and comparable reproducibility with MRI and mammography for characterizing breast cancer lesions. Clinical relevance The findings prove that CE-CBBCT could combine morphology, hemodynamic, and calcification features and provide support for the feasibility of applying the BI-RADS descriptors of MRI and mammography to interpret contrast-enhanced cone-beam breast CT images in clinic.
More Related Videos
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound
Published on: August 14, 2012
06:44Modeling Brain Metastases Through Intracranial Injection and Magnetic Resonance Imaging
Published on: June 7, 2020
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT