Evaluation of the Cognitive Performance of Hypertensive Patients with Silent Cerebrovascular Lesions
Published on: April 23, 2021
Higher blood pressure variability during hospitalisation is associated with lower cerebral white matter integrity in
Theresa J van Lith1, Esther Janssen1, Jan-Willem van Dalen1,2
1Department of Neurology, Donders Center for Medical Neuroscience, Radboud University Medical Center, Nijmegen, the Netherlands.
Background:
High blood pressure variability (BPV) is associated with cerebrovascular damage and dementia, but it is unknown whether short-term BPV during hospitalisation is also associated with cerebral white matter (WM) damage. We examined whether BPV, measured in-hospital using continuous monitoring, is associated with WM microstructural integrity in COVID-19 patients.
Methods:
We included hospitalised COVID-19 patients from the CORONavirus and Ischemic Stroke (CORONIS) study who underwent continuous vital signs monitoring using a wearable device during hospital admission and had an MRI shortly after discharge. Systolic BPV was calculated as Average Real Variability (ARV) and Coefficient of Variation (CV) with 1-, 5- and 20-minute intervals. We used diffusion tensor imaging to assess fractional anisotropy (FA) and peak width of skeletonised mean diffusivity (PSMD) as markers of WM integrity. Associations between BPV and WM integrity were examined with linear regression adjusted for age, mean systolic blood pressure (BP), number of BP measurements and type of respiratory support.
Results:
We included 47 COVID-19 patients (mean age: 59.6 years). BP was measured 6306 ± 4343 times per patient (median admission: 11 days (Interquartile Range [IQR] 7.5-15.0). Both higher ARV and CV were associated with lower WM microstructural integrity, reflected by lower FA (ARV: β = -0.40, p = .010; CV: β = -0.33, p = 0.026) and higher PSMD (CV: β = 0.28, p = .038) after adjustment for confounders. Correction for WM hyperintensities did not change these results.
Conclusions:
High BPV during hospitalisation is associated with lower WM integrity in COVID-19 patients, although causality needs to be demonstrated. Our findings need validation in hospitalised patients without COVID-19 to examine generalisability.
More Related Videos
Related Concept Videos
Measurement of Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Factors affecting Blood pressure
Physiological Factors:
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...
Hypertension and Regulation of Blood Pressure