Imaging the ex-vivo human cochlea using 1.3-μm and 1.7-μm optical coherence tomography
Jack C Tang1, Dorothy W Pan1, John S Oghalai1,2
1University of Southern California, Caruso Department of Otolaryngology-Head and Neck Surgery, Los Angeles, California, United States.
Significance:
There is no clinical imaging method to visualize the soft tissues of the human cochlea, which are crucial for sound transduction and are damaged in sensorineural hearing loss. Although optical coherence tomography (OCT) has been effective in small animal models, we show for the first time that it can image through the full thickness of the ex-vivo human otic capsule and resolve cochlear microstructures despite increased scattering.
Aim:
We aim to investigate whether OCT could image the cochlea through the otic capsule. We compared 1.7 and OCT to test if the reduced scattering at provided any appreciable advantage for imaging the cochleae.
Approach:
OCT interferometers were built for both 1.3 and wavelengths, using identical sample and reference arm optics in both systems. Imaging was performed on two fixed human temporal bones with intact cochleae. The interferometers were designed to allow seamless switching between 1.3 and OCT without disrupting the temporal bone during imaging.
Results:
We took volumetric OCT images at the base, apex, and hook regions of fixed ex-vivo human cochleae and compared the images taken at with those taken at . At both wavelengths, we could see through the otic capsule and identify cochlear structures. In some cases, OCT resulted in clearer images of the lateral wall, interior scala, and fine cochlear structures due to reduced multiple scattering at depth compared with .
Conclusions:
We conclude that both and OCT can image through the human otic capsule, offering the potential for direct measurement of cochlear vibrometry or blood flow in living humans. Using light, we observed reduced multiple scattering in the otic capsule, leading to enhanced contrast of cochlear structures compared with . However, these improvements were marginal and came with trade-offs.
More Related Videos
Related Concept Videos
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
X-ray Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Magnetic Resonance Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...